BLOWER/WATTS DATA

G43UF−24B−045−1, −3 PERFORMANCE
External
Air Volume / Watts at Different Blower Speeds
Static
Static
High
Pressure
in.
Pa
cfm
L/s Watts
w.g.
0.00
0
975
460
380
0.10
25
935
440
365
0.20
50
910
430
360
0.30
75
870
410
345
0.40
100
825
390
330
0.50
125
760
360
315
0.60
150
725
340
310
0.70
175
680
320
295
0.80
200
620
290
285
0.90
225
555
260
270
NOTES − All air data is measured external to unit with1 in. foam filter (not furnished − field provided).
Air volume based on bottom air return air. Actual air volume may vary on side return air applications.
G43UF−24B−045−4 PERFORMANCE (Less Filter)
External Static
External Static
Pressure
in. w.g.
Pa
cfm
0.00
0
1125
0.10
25
1115
0.20
50
1090
0.30
75
1060
0.40
100
1020
0.50
125
970
0.60
150
920
0.70
175
860
0.80
200
760
0.90
225
675
G43UF−24B−070−4 PERFORMANCE (Less Filter)
External Static
External Static
Pressure
in. w.g.
Pa
cfm
0.00
0
1115
0.10
25
1115
0.20
50
1100
0.30
75
1080
0.40
100
1050
0.50
125
1010
0.60
150
980
0.70
175
930
0.80
200
855
0.90
225
770
NOTES − All air data is measured external to unit without filter (not furnished − field provided).
Air volume based on bottom air return air. Actual air volume may vary on side return air applications.
Medium
Low
cf
cf
L/s Watts
L/s Watts
m
m
870
410
340
720
340
855
400
335
710
335
830
390
325
680
320
795
375
310
655
310
760
360
300
630
295
715
335
285
610
290
675
320
280
580
275
630
300
265
545
260
575
270
255
495
235
520
245
245
425
200
Air Volume / Watts at Different Blower Speeds
High
Medium−High
L/s
Watts
cfm
530
425
900
525
410
905
515
395
895
500
380
880
480
365
860
460
345
835
435
335
795
405
315
730
360
295
665
320
275
585
Air Volume / Watts at Different Blower Speeds
High
Medium−High
L/s
Watts
cfm
525
435
875
525
425
865
520
415
870
510
400
870
495
385
855
475
365
835
460
355
810
440
340
770
405
320
720
365
295
650
G43UF−24B−070−1, −3 PERFORMANCE
External
Air Volume / Watts at Different Blower Speeds
Static
Static
Pressure
in.
Pa
cfm
w.g.
285
0.00
25
1020 480
280
0.10
25
985
270
0.20
50
945
260
0.30
75
905
255
0.40
100
860
250
0.50
125
810
235
0.60
150
740
230
0.70
175
700
220
0.80
200
635
205
0.90
225
555
Medium−Low
L/s
Watts
cfm
425
360
745
425
350
760
420
335
755
415
325
740
405
315
720
395
300
700
375
290
665
345
270
620
315
250
560
275
230
495
Medium−Low
L/s
Watts
cfm
415
360
720
410
350
725
410
335
730
410
330
725
405
320
715
395
310
695
380
295
675
365
285
640
340
270
585
305
250
525
Page 4
High
Medium
L/s Watts cfm
L/s Watts cfm
380
905
430
345
465
370
890
420
330
445
355
860
405
325
430
345
830
390
315
405
330
790
370
300
380
320
750
355
290
350
305
710
335
280
330
295
650
305
265
300
280
590
280
255
260
265
530
250
235
L/s
Watts
cfm
350
295
690
360
285
695
355
280
685
350
270
675
340
260
665
330
255
640
315
240
600
295
230
565
265
215
510
235
200
500
L/s
Watts
cfm
340
290
665
340
285
670
345
280
665
340
270
655
335
265
645
330
255
625
320
250
600
300
235
565
275
220
520
245
205
465
Low
L/s Watts
740
350
280
730
345
270
705
330
265
690
325
260
660
310
250
630
300
240
590
280
230
550
260
220
495
235
210
425
200
195
Low
L/s
Watts
325
265
330
260
325
255
320
250
315
240
300
230
285
220
265
215
240
200
190
175
Low
L/s
Watts
315
255
315
255
315
250
310
240
305
240
295
230
285
225
265
215
245
200
220
190

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents