Testing Gas Supply Pressure; Check Manifold Pressure; Gas Pipe Capacity - Lennox G43UF SERIES Unit Information

Hide thumbs Also See for G43UF SERIES:
Table of Contents

Advertisement

Nominal
Nominal
Internal
Internal
Iron Pipe Size
Diameter
−Inches(mm)
−Inches(mm)
1/4
.364
(6.35)
(9.246)
3/8
.493
(9.53)
(12.522)
1/2
.622
(12.7)
(17.799)
3/4
.824
(19.05)
(20.930)
1
1.049
(25.4)
(26.645)
1−1/4
1.380
(31.75)
(35.052)
1−1/2
1.610
(38.1)
(40.894)
2
2.067
(50.8)
(52.502)
2−1/2
2.469
(63.5)
(67.713)
3
3.068
(76.2)
(77.927)
4
4.026
(101.6)
(102.260)
NOTE−Capacity given in cubic feet of gas per hour (kilo liters of gas per hour) and based on 0.60 specific gravity gas.
IMPORTANT
The furnace must be isolated from the gas supply
piping system by closing its individual manual
shut−off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig (3.45 kPa).
The furnace and its individual shut−off valve must
be disconnected from the gas supply piping sys-
tem during any pressure testing of the system at
test pressures greater than 1/2 psig (3.45 kPa). See
figure 39.
When checking piping connections for gas leaks, use pre-
ferred means. Kitchen detergents can cause harmful corro-
sion on various metals used in gas piping. Use of a specialty
Gas Leak Detector is strongly recommended. It is available
through Lennox under part number 31B2001. See Corp.
8411−L10, for further details.
WARNING
Do not use matches, candles, flame or any other
source of ignition to check for gas leaks.
D−Testing Gas Supply Pressure
When testing supply gas pressure, use the 1/8" N.P.T.
plugged tap or pressure post located on the gas valve to
facilitate test gauge connection. See figure 14. Check gas
TABLE 15
GAS PIPE CAPACITY − FT
10
20
30
(3.048)
(6.096)
(9.144)
43
29
24
(1.13)
(.82)
(.68)
95
65
52
(2.69)
(1.84)
(1.47)
175
120
97
(4.96)
(3.40)
(2.75)
360
250
200
(10.19)
(7.08)
(5.66)
680
465
375
(19.25)
(13.17)
(10.62)
1400
950
770
(39.64)
(26.90)
(21.80)
2100
460
1180
(59.46)
(41.34)
(33.41)
3950
2750
2200
(111.85)
(77.87)
(62.30)
6300
4350
3520
(178.39)
(123.17)
(99.67)
11000
7700
6250
(311.48)
(218.03)
(176.98)
23000
15800
12800
(651.27)
(447.39)
(362.44)
Page 34
/HR (kL/HR)
3
Length of Pipe−Feet(m)
40
50
60
(12.192)
(15.240)
(18.288)
20
18
16
(.57)
(.51)
(.45)
45
40
36
(1.27)
(1.13)
(1.02)
82
73
66
(2.32)
(2.07)
(1.87)
170
151
138
(4.81)
(4.28)
(3.91)
320
285
260
(9.06)
(8.07)
(7.36)
660
580
530
(18.69)
(16.42)
(15.01)
990
900
810
(28.03)
(25.48)
(22.94)
1900
1680
1520
(53.80)
(47.57)
(43.04)
3000
2650
2400
(84.95)
(75.04)
(67.96)
5300
4750
4300
(150.07)
(134.50)
(121.76)
10900
9700
8800
(308.64)
(274.67)
(249.18)
line pressure with unit firing at maximum rate. Low pres-
sure may result in erratic operation or underfire. High pres-
sure can result in permanent damage to gas valve or over-
fire. For natural gas units, operating pressure at unit gas
connection must be between 4.5" W.C. and 13.0" W.C. For
L.P. gas units, operating pressure at unit gas connection
must be between 10.5" and 13.0" W.C.
On multiple unit installations, each unit should be checked
separately, with and without units operating. Supply pres-
sure must fall within range listed in previous paragraph.
E−Check Manifold Pressure
Manifold pressure is the manifold pressure measured
when the gas valve regulator is operating at factory preset
level sensing atmospheric pressure.
IMPORTANT
The White Rodgers 36G gas valve (figure 14) is
equipped with pressure posts for measuring supply
and manifold pressures. The posts provide built−in
hose connections and have an integral 3/32" Allen−
head screw. Rotate the screw counterclockwise one
full turn to permit pressure measurement. Reseat the
screw (rotate one full turn clockwise) after measure-
ments have been taken to prevent gas leakage.
After line pressure has been checked and adjusted, check
manifold pressure. Move pressure gauge to outlet pres-
sure tap located on unit gas valve (GV1).
70
80
90
(21.336)
(24.384)
(27.432)
15
14
13
(.42)
(.40)
(.37)
33
31
29
(.73)
(.88)
(.82)
61
57
53
(1.73)
(1.61)
(1.50)
125
118
110
(3.54)
(3.34)
(3.11)
240
220
205
(6.80)
(6.23)
(5.80)
490
460
430
(13.87)
(13.03)
(12.18)
750
690
650
(21.24)
(19.54)
(18.41)
1400
1300
1220
(39.64)
(36.81)
(34.55)
2250
2050
1950
(63.71)
(58.05)
(55.22)
3900
3700
3450
(110.43)
(104.77)
(97.69)
8100
7500
7200
(229.36)
(212.37)
(203.88)
100
(30.480)
12
(.34)
27
(.76)
50
(1.42)
103
(2.92)
195
(5.52)
400
(11.33)
620
(17.56)
1150
(32.56)
1850
(52.38)
3250
(92.03)
6700
(189.72)

Hide quick links: