Diagnostic Codes - Lennox G40UH(X) Unit Information

Table of Contents

Advertisement

The ignition control is equipped with two LED lights for troubleshooting. The diagnostic codes are listed below in table 4.
LED #1
DS #1
AN #1
SIMULTANEOUS
SLOW FLASH
SIMULTANEOUS
FAST FLASH
SLOW FLASH
OFF
ALTERNATING
SLOW FLASH
SLOW FLASH
ON
ON
ON
OFF
FAST FLASH
SLOW FLASH
ALTERNATING
FAST FLASH
NOTE − Slow flash rate equals 1 Hz (one flash per second). Fast flash rate equals 3 Hz (three flashes per second).
1
É É É É
ON
É É
OFF
É É É É É É É É É É É É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É É É É É É É É É É
DEMAND
CAI
É É É É É É É É É É É É É É É É É É É É É É É É É É
IGNITOR
GAS VALVE
INDOOR BLOWER
*Blower on time will be 45 seconds after gas valve is energized. Blower off time will depend on OFF TIME" Setting.
**Ignitor on control 57L84 will energize for the first second ONLY of the 4 second ignition trial
***ignitor on control 78M47 & 100973−01 will energize the first three seconds ONLY of the 4 second ignition trial

DIAGNOSTIC CODES

Make sure to Identify LED'S Correctly.
Refer to figures 5 and 8 for control board layout.
LED #2
DS #2
AN #2
Power on − Normal operation.
SIMULTANEOUS
Also signaled during cooling and continuous fan.
SLOW FLASH
SIMULTANEOUS
Normal operation − signaled when heating demand initiated at thermostat.
FAST FLASH
Primary or secondary limit switch open. Limit must close within 3 minutes or unit
ON
goes into 1 hour Watchguard.
Prove switch open.
SLOW FLASH
OR: Blocked inlet/exhaust vent;
OR: Prove switch closed prior to activation of combustion air inducer.
ALTERNATING
Watchguard −− burners failed to ignite.
SLOW FLASH
OFF
Flame sensed without gas valve energized.
SLOW FLASH
Rollout switch open. OR: 24V pin connector improperly attached.
ON
Circuit board failure or control wired incorrectly.
OFF
ON
SLOW FLASH
Main power polarity reversed. Switch line and neutral.
FAST FLASH
Low flame signal. See Table 15 for flame sense.
The following conditions are sensed
Improper main ground (Control 10M93, 57L84) during ignitor warm up period
ONLY, improper main ground continuously (Control 78M47 & 100973−01)
ALTERNATING
OR: Broken ignitor (Control 10M93, 57L84)
FAST FLASH
OR: Open ignitor circuit (Control 78M47 & 100973−01)
OR: Line voltage below 75V (Control 10M93, 57L84) 90V (Control 78M47 &
IGNITION CONTROL 10M93 & 56L84** & 78M47*** & 100973−01
15
Pre −Purge
Ignitor Warm−up
É É É É É É É É É É
É É É É É É É É É É
TABLE 4
DESCRIPTION
100973−01)
34
38
Trial for
Blower On"
Ignition
Delay
É É É É É É É É É É É É É
FIGURE 7
Page 18
y
80
5 SEC
Post
Purge
É É É É É É É É É
É É É É É É É É É

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents