Check Power Supply Connection; Designating Heating Circuits; Select Gas Type - Viessmann VITODENS 200-W Service Instructions Manual

Table of Contents

Advertisement

Vitodens 200-W B2HA 19, 28, 35 Service

Check Power Supply Connection

An external accessories connection box is attached to
the Vitodens 200-W, B2HA boiler, which requires a
120VAC power supply from a wall receptacle (12A fuse
protected).
Refer to the Installation Instructions shipped with the
boiler.
Voltage range
The voltage at connector 40 of the boiler control must be
120V (see wiring diagram).
Neutral conductor
The electrical power supply must have a neutral
conductor.

Designating Heating Circuits

Select Gas Type

Heating value (gross)
Specific gravity
Ultimate carbon dioxide (CO
Btu/ft
3
)
%
2
IMPORTANT
In Canada all electrical wiring is to be done in accordance
with the latest edition of CSA C22.1 Part 1 and/or local
codes. In the U.S. use the National Electrical Code ANSI/
NFPA 70. The heating contractor must also comply with
both the Standard for Controls and Safety Devices for
Automatically Fired Boilers, ANSI, ASME CSD-1.
Note: The outer conductor "L " and the neutral conductor
"N" must not be interchanged.
See wiring diagram on page 88 in section entitled
"Additional Information".
In the delivered condition, the heating circuits are
designated "Heating circuit 1", "Heating circuit 2" and
"Heating circuit 3" (if installed).
If the system user prefers, the heating circuits can be
designated differently to suit the specific system.
To enter names for heating circuits:
Refer to the Operating Instructions
Note: the Vitodens 200-W, B2HA boiler is factory set to
operate with natural gas. See following subsection
for conversion instructions to liquid propane gas.
1. Ensure that the fuel type listed on the boiler rating
plate is the correct type for the installation being
attempted.
2. Record fuel type in Maintenance Record on page 96.
The Vitodens 200-W boiler is for use with gases whose
characteristics fall within the following ranges.
Do not use any other types of gas.
Natural gas
970 to 1100
0.57 to 0.70
11.7 to 12.2
Start-up and Service
Liquid propane gas
2466 to 2542
1.522 to 1.574
13.73 to 13.82