Electrical Connections - Biasi RIVA OV M110.18SM/OV User Manual And Installation Instructions

Wall hung, fan flue, room sealed, high efficiency gas boiler
Table of Contents

Advertisement

Fig. 15.
Installing the flue system
from inside the room
FIBRE
SEAL FITTED
e) Finally locate and
appliance using the four screws provided.
4.7.2
Installing the Air/Flue Duct from
outside the building
(Flue hole diameter 100 mm - wall liner not
necessary)
a) Secure the flue elbow with seal to the
appliance using 4 screws.
b) Fit external wall sealing ring over flue and
then from outside the building, push the flue
system through the wall taking care to ensure
that the terminal is the correct way around.
c) Loosely fit the internal wall sealing ring over
the inside end of the flue.
d) Assemble the flue system extension ducts as
necessary,
referring
instructions, and fit to the flue elbow.
e) Fit the flue terminal to the flue system,
ensuring that the duct joints are not
disturbed, and that the external sealing ring
is seated against the outside wall.
f) Finally use the internal sealing ring to make
good the internal hole. Check that the
external wall sealing ring and the terminal is
correctly located, on the outside wall from
outside the building.
4.8

Electrical Connections

Connect the electricity supply and
controls (using suitable mains cable) as follows:
20
INTERNAL WALL
SEALING RING
2 ALIGN ASSEMBLED
FLUE SYSTEM ELBOW
TO APPLIANCE AND
SECURE
secure the elbow to the
to
the
flue
external
3 SLIDE
INTERNAL WALL
SEALING RING
TO WALL TO
FORM A GOOD
SEAL
Wire
the
cable(s)
connections in the electrical plug provided,
referring to Figure 16. Live supply to L1, Neutral
and Earth as indicated. Check that L1 and L3
are linked.
To provide correct cable retention, fit the piece
of tubing supplied over the cable as it passes
through the clamping arrangement. The cable
will be held in position as the plug cover is
fitted.
If a programmer/room thermostat is to be fitted
remove the red link between L1 and L3 and
connect the device across these terminals. Any
external controls fitted must be rated at 230V
50Hz and have volt free contacts.
Fig. 16.
kit
130mm Dia.
TOP
HOLE WITH
WALL LINER
EXTERNAL
SEALING RING
1
INSERT
ASSEMBLED
FLUE
SYSTEM
FROM INSIDE
THE ROOM.
EXTERNAL
WALL
SEALING
RING OPENS
into
the
appropriate
WALL