Beverage too warm
CO2-Volume in the
drink too low
(target:~3,0Vol/~6,0g
per Liter) measure
carbonisation values
efficient
Stop signal in aqua
display
Temperature setting too high
Condenser dirty
Fan motor dirty or defect
Air intake / exit blocked or unit placed too
close to wall
Cooling circuit / compressor defect
Too much beverage dispensed in short
time
CO
-pressure in carbonator too low
2
CO
-bottle empty
2
Main water pressure too low
Drink temperature set too high, CO
escaping the water
Dirty stainless steel filter at main water (if
exists)
Hygiene filter at main water (if exists)
Too much beverage dispensed in short
time
Sensor wet at base plate (see capture X)
Sensor wet in drip try
POU WATERDISPENSER
Readjust temperature at thermostat
Clean condenser with brush or
compressed air / CO
Clean / exchange fan motor
Ensure that air circulation is
sufficient
Repair cooling circuit
Explain customer max. cooling
performance
Readjust CO
Exchange CO
Ensure water flow pressure of 2,5
bar after filter
2
Readjust thermostat to lower setting
Open stainless steel filter and clean
Exchange the hygiene filter to new
Explain customer max. cooling
performance
Dry sensor and find reason for
leakage
Emptying the drip tray if necessary
find the reason for leakage.
22
PearlMini
2
-pressure
2
-bottle
2

Hide quick links: