Cornelius Quest 4000 Installation Manual
Cornelius Quest 4000 Installation Manual

Cornelius Quest 4000 Installation Manual

Cornelius quest 4000 juice dispenser installation manual
Hide thumbs Also See for Quest 4000:

Advertisement

Quick Links

QUEST 4000
Installation Manual
Release Date: August 17, 2006
Publication Number: 720901117INS
Revision Date: January 9, 2011
Revision: E
Visit the IMI Cornelius web site at www.cornelius.com for all your Literature needs.

Advertisement

Table of Contents
loading

Summary of Contents for Cornelius Quest 4000

  • Page 1 QUEST 4000 Installation Manual Release Date: August 17, 2006 Publication Number: 720901117INS Revision Date: January 9, 2011 Revision: E Visit the IMI Cornelius web site at www.cornelius.com for all your Literature needs.
  • Page 2 Commercial Warranty. Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting from any of the following occurrences, including but not limited to, (1) other than normal and proper use and normal...
  • Page 3: Table Of Contents

    Safety Instructions..............1 Read and Follow ALL Safety Instructions .
  • Page 4: Safety Instructions

    Quest 4000 Installation Manual SAFETY INSTRUCTIONS ALL S EAD AND OLLOW AFETY NSTRUCTIONS Safety Overview • Read and follow ALL SAFETY INSTRUCTIONS in this manual and any warning/caution labels on the unit (decals, labels or laminated cards). • Read and understand ALL applicable OSHA (Occupational Safety and Health Administration) safety regulations before operating this unit.
  • Page 5 Quest 4000 Installation Manual AFETY RECAUTIONS This unit has been specifically designed to provide protection against personal injury. To ensure continued protection observe the following: WARNING: Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify all of the power is off to the unit before any work is performed.
  • Page 6: Electrical Connection

    Quest 4000 Installation Manual REQUIREMENTS Figure 1. Unit Dimensions Nameplate Data Model QST 4000, 115 VAC, 4.5 amps, 1 phase 60 hertz, 6.75 oz. (191-193g) R-134a refrigerant. Test press: High side 400 psi (27.6 bar). Low side 100 psi (6.9 bar).
  • Page 7: Water Supply Requirements

    Quest 4000 Installation Manual Water Supply Requirements 60 psi (413.7 kilopascals) (4.1 bar) maximum static pressure. 30 psi (206.8 kilopascals) (2.1 bar) minimum dynamic pressure; i.e., flowing pressure measured at dispenser water inlet with 3.0 (88.7 ml) per second water flow. Optimum recommended pressure 50 psi (344.7 kilopascals) (3.5 bar) dynamic pressure.
  • Page 8 Quest 4000 Installation Manual ILLING THE The ice bath holds approximately 3 gallons (11.4 liters) of water. The fill tube is located behind the front splash plate and capped with a 3/8” (0.95 cm) male flare connector. Prior to attaching the water supply line to the dispenser, use it to fill the ice bath by attaching it to the connector on the fill tube.
  • Page 9 Quest 4000 Installation Manual LECTRICAL A minimum of 15 amps electrical service is needed for 120VAC power supply. A minimum of 20 amps electrical service is needed for 230VAC power supply. RIMING LUSHING ATER YSTEM To properly prime the unit with water and remove air pockets in the system, open the cabinet door and make sure that all the valve levers are in the Dispense position.
  • Page 11 IMI Cornelius Inc. www.cornelius.com...

Table of Contents