Section 4: Wiring - Montigo PL52DFN-I Installation & Maintenance Manual

Pl series
Table of Contents

Advertisement

Section 4: Wiring

Models
PL52DFN-F
PL52DFL-F
BATTERY
PACK
1.5V AA type
1.5V AA type
1.5V AA type
RED
1.5V AA type
BLACK
885 PROFLAME
CPI/IPI SWITCH
YELLOW/GREEN
ORANGE
PILOT
GREEN
BLACK
BROWN
YELLOW
BURNER
ORANGE
Installations in Canada must be electrically grounded in
accordance with CSA C22.1 Canadian Electrical Code Part
1 and/or Local Codes.
Installations in the USA must be grounded in accordance
with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
NOTE: If any of the original wire supplied with the appliance
is replaced, it must be replaced with the same type, or its
equivalent.
XG0218 - 160215
Installation
SPARK
SENSOR
MAIN ON/OFF
SWITCH
6
jumper
BLUE
WHITE
10
4
6
3
LED Lights
4
LED1 - Red LED
LED2 Amber LED
Figure 17. Wiring Diagram for PL52DF with SIT Proflame 2 Electronic Ignition
X2
X1
X3
X4
X5
X6
X10
X11
X12
X13
SW1
Figure 18. Electrical connection access.
PL52DF* Indoor Gas Fireplace
GREEN
MAIN
WHITE
Power
BLACK
120VAC 60 Hz
6 Amps
Optional
VARIABLE SPEED
COMFORT FANS
Blk
Wht
Wht
Blk
BLACK
WHITE
5½"
5"
5½"
5"
2½"
0.8"
2½"
0.8"
8"
8"
Page 19