Ibm 6400 Main Wire Harness Test Tables - IBM 6400 series Maintenance Manual

Hide thumbs Also See for 6400 series:
Table of Contents

Advertisement

Top view; as seen when plugged
PIN NO.
into the CMX board.
19
17
15
13
11
9
7
5
3
1
POD
CCF
PLAT M
PMD
LRP
LRIB M
20
18
16
14
12
10
8
6
4
2
CCF = Card Cage Fan
LRIB M = Left Ribbon Motor
LRP = Left Ribbon Post
PLAT M = Platen Open Motor
PMD = Paper Motion Detect (Switch)
POD = Paper Out Detect (Switch
Resistance
Device
P106 Pins
Normal
7.2 – 8.8 Ω
LRIB M
2, 4 and 6, 8
1.35 – 1.65 Ω
PLAT M
1, 3 and 5, 7
LRP
10, 12
Open across pins
Short across post
CCF
9, 11
4.6 KΩ
PMD
14, 16
8 MegΩ
18, 20
Open
POD
13, 15
8 MegΩ
17, 19
Open
P106
NOTE: For cable shell connector
assembly/disassembly, see
Figure 30 on page 199.
Main Wire Harness Test Tables
Top view; as seen when plugged
into the CMX board.
19
17
15
13
11
9
7
5
P107
MPU
PLO
EHF
PAPR M
CVO
RRP
HBF
RRIB M
20
18
16
14
12
10
8
6
Device
RRIB M
PAPR M
HBF
EHF
RRP
PLO
CVO
MPU
IBM 6400
PIN NO.
3
1
4
2
CVO = Cover Open (Switch)
EHF* = Exhaust Fan
HBF = Hammer Bank Fan
MPU = Magnetic Pickup
PAPR M = Paper Feed Motor
PLO = Platen Open (Switch)
RRIB M = Right Ribbon Motor
RRP = Right Ribbon Post
*Only in cabinet models
Resistance
P107 Pins
Normal
7.2 – 8.8 Ω
2, 4 and 6, 8
0.417 – 0.681 Ω
1, 3 and 5, 7
10, 12
2.7 KΩ
9, 11
4.6 KΩ
14, 16
Open across pins
Short across post
13, 15
Continuity: switch closed
Open: switch open
18, 20
Continuity: switch closed
Open: switch open
670 Ω
17, 19

Advertisement