Technical Data For Electric Hc Units - WAGNER HC 920 Operating Manual

Airless high-pressure spraying unit
Table of Contents

Advertisement

Available languages

Available languages

Description of unit
3.8

Technical data for electric HC units

Voltage
230 V~, 50 Hz:
400 V, 50 Hz, V3~:
Fuse protection
16 A:
Power cord
2
3 x 2.5 mm
– 6 m:
2
5 x 2.5 mm
– 6 m:
Capacity
3.1 kW:
5.5 kW:
Max operating pressure
22.8 MPa (228 bar):
Maximum volume flow
5.5 l/min:
6.6 l/min:
10 l/min:
Volume flow at 12 MPa (120 bar)
4.8 l/min:
5.2 l/min:
10 l/min:
Max. size of tip with a spray gun
0.043 inch – 1.10 mm:
0.052 inch – 1.30 mm:
0.056 inch – 1.42 mm:
Max. temperature of the coating material
43° C:
Max. Viscosity
40.000 mPa·s:
50.000 mPa·s:
65.000 mPa·s:
Filter insert (standard equipment)
5 Maschen:
0 Maschen:
Weight:
83 kg
84.5 kg
100 kg
103 kg
Hydraulic oil filling quantity
4.7 l ESSO Nuto H 32:
Max. tire pressure
0.2 MPa (2 bar):
Special high-pressure hose
DN 10 mm, 15 m, connection thread NPSM 3/8:
DN 13 mm, 15 m, connection thread NPSM 1/2:
DN 19 mm, 15 m, connection thread NPSM 3/4:
Hose whip
DN 10 mm, 2,5 m, connection thread NPSM 3/8:
Dimensions L x W x H
1160 x 955 x 655 mm:
1185 x 955 x 655 mm:
1200 x 955 x 655 mm:
Max. sound pressure level:
77 dB (A)*
80 dB (A)*
88 dB (A)*
* Place of measurement: 1 m distance from unit and 1.60 m above reverberant floor, 12 MPa (120 bar) operating pressure.
GB
HC 920
HC 940
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
38
HC 940-SSP
HC 960
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
HC 920 • HC 940 • HC 960
HC 960-SSP
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hc 940Hc 960Hc 940-sspHc 960-ssp

Table of Contents