Indirect Length Measurement; Clearing The Measured Values; Storing The Measured Values; Adding/Subtracting Measured Values - Bosch DLE 150 Connect Operating Instructions Manual

Digital laser rangefinder
Hide thumbs Also See for DLE 150 Connect:
Table of Contents

Advertisement

Indirect Length Measurement (see Fig.
The indirect length measuring function serves for measuring distances
that cannot be measured directly because an obstacle would obstruct the
laser beam or no target surface is available as a reflector. The best pos-
sible results are achieved only when the laser beam and the measured
distance form an exact right angle (Pythagorean theorem).
In the illustrated example, the length "C" is to be determined. For this pur-
pose, "A" and "B" must be measured.
Press the indirect length measurement button
mode for indirect length measuring. The symbol for indirect measuring
appears in the display.
The individual measured values "A" and "B" are shown at the upper right
and are automatically transmitted after each measurement.
After completion of the second measurement, the length "C" is automat-
ically calculated by the DLE 150 Connect and shown at the bottom of the
display. The "C" value is not transmitted.

Clearing the Measured Values

By pressing the
mined individual measured value is possible.
Already transmitted measured values must be cleared in the "BOSCH
DLE 150" software or in the application software used (see Working with
the "BOSCH DLE 150" Software). The clearing is not possible by means
of the DLE 150 Connect.

Storing the Measured Values

The unit makes possible the storing of the measured values by two meth-
ods:
Adding/subtracting measured values: The results of individual
measurements can be added or subtracted and the sum or difference
displayed.
List of the last 20 measured results: In addition, the unit stores au-
tomatically the results of the last 20 measurements and can display
them.
Both methods of storing are called up with the memory recall button
14.
The transmission of stored measured values is not possible. If transmitted
measured values are to be added or subtracted, this must take place in
an application software on the PC or PDA.
1 609 929 F53 • (04.07) T
As for a length measurement, measure the
distance "A". Take care that a right angle ex-
ists between the laser beam and the distance
"C". Then measure distance "B".
During the measurements, the rear end of the
unit as the reference point must remain at the
same position.
clear button 12, the correction of the last deter-
By repeated pressing of the clear button
, several individual measured values are
cleared one after the other in the reverse order
of the measurement.
By pressing the
tinuous measurement functional mode, the
minimum and maximum measured values are
both cleared at the same time.
English–15
)
F
13 to switch to the
clear button in the con-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents