Slant/Fin Victory VSP-60 Installation And Operating Instructions Manual page 9

Hide thumbs Also See for Victory VSP-60:
Table of Contents

Advertisement

V
ICTORY VSP Models
VICTORY VSP MODELS NON - DIRECT VENT, SIDEW LL VENTING
BUILT-IN
CONDENSATION
DRAIN & TRAP
FILL TRAP
WITH WATER
AIR INTAKE
(DO NOT BLOCK)
VSP BOILER
Figure 5. Non-direct vent, side wall venting.
BUILT-IN
CONDENSATION
DRAIN & TRAP
FILL TRAP
WITH WATER
AIR INTAKE
(DO NOT BLOCK)
VSP BOILER
Figure 6. Non-direct vent, side wall venting.
Definition of Snow Line: Knowledge of local conditions will reveal the maximum height that repeated snowfalls accumulate to.
The height should be used as the SNOW LINE.
AL 29-4C IS A REGISTERED TRADEMARK OF ALLEGHENY LUDLUM CORP
*
All joints must be liquid and pressure tight. Use U/L listed single wall 3" dia.
AL29-4C S.S.*. venting materials (See page 5).
SLOPE UP 1/4 IN.
PER FOOT MIN.
FROM BOILER TO
VENT TERMINATION
TO DRAIN OR
CONTAINER
SLOPE UP 1/4 IN.
PER FOOT MIN.
FROM BOILER TO
VENT TERMINATION
STANDARD 90˚
ELBOW
STANDARD 90˚ ELBOW
TIGHT RADIUS 90˚ ELBOW
TO DRAIN OR
CONTAINER
2 FT. MIN.
6 IN. MIN.
9 IN. MAX.
OUTSIDE VENT TERMINATION
A WALL THIMBLE MUST
BE USED ON COMBUSTIBLE
WALLS. S/F P/N 440695
3 IN. DIA.
(ADJUSTABLE 5 IN. TO 8 IN.)
S.S. FLUE
MAY BE USED. ABOVE THIMBLE
PIPE (SEE
MUST BE USED WITH HEAT-FAB
PAGE 5)
SLIP JOINT CONNECTOR
OUTSIDE WALL
A U/L LISTED WALL THIMBLE
MUST BE USED ON COMBUSTIBLE
3 IN. DIA.
WALLS. S/F P/N 440695
S.S. FLUE
(ADJUSTABLE 5 IN. TO 8 IN.)
PIPE (SEE
MAY BE USED. ABOVE THIMBLE
PAGE 5)
MUST BE USED WITH HEAT-FAB
SLIP JOINT CONNECTOR
OR
OUTSIDE
WALL
.
ELBOW WITH SCREEN
12" MIN
SNOW LINE
(SEE DEFINITION)
6 IN.
9 IN.
X.
OUTSIDE VENT TERMINATION
ELBOW WITH SCREEN
12" MIN
SNOW LINE
(SEE DEFINITION)
9