SiENBE04-401A
Indoor Units
Models
Outdoor Units
Capacity
Rated (Min.~Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min.~Max.)
Power Factor
COP (Rated)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Indoor Units
Front Panel Color
mł/min
Air Flow Rate
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Outdoor Units
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant
Oil
Charge
Type
Refrigerant
Charge
mł/min
Air Flow Rate
(cfm)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power
Drawing No.
Note:
Outdoor ; 35°CDB/24°CWB
Specifications
kW
Btu/h
11,600 (4,750~12,950)
kcal/h
2,920 (1,200~3,270)
L/h
A
W
1,060 (300~1,300)
%
W/W
mm
mm
mm
H
M
L
SL
W
Steps
A
W
%
mm
mm
kg
kg
dBA
dBA
W
L
kg
H
L
W
A
W
%
A
mm
mm
kg
kg
dBA
dBA
MAX. interunit piping length: 20m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 7°CDB/6°CWB
FTXS35CAVMB
RXS35C2VMB
Cooling
3.4 (1.4~3.8)
1.9
4.9
94.3
3.21
φ 6.4
φ 9.5
φ 18.0
Both Liquid and Gas Pipes
FTXS35CAVMB
White
7.7 (272)
6.0 (212)
4.4 (155)
3.8 (134)
Cross Flow Fan
5 Steps, Silent, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.18
40
96.6
Microcomputer Control
273×784×195
258×834×325
39 / 33 / 26 / 23
57
RXS35C2VMB
Ivory White
Hermetically Sealed Swing Type
1YC23NXD#A
FVC50K
0.375
R-410A
1.00
31.3 (1,105)
22.4 (791)
Propeller
4.72
1,020
94.0
550×765×285
589×882×363
47 / 44
62
3D050945
Heating
Piping Length
Indoor ; 20°CDB
7.5m
Heating
4.0 (1.4~5.0)
13,650 (4,750~17,050)
3,440 (1,200~4,300)
5.4
1,170 (310~1,590)
95.4
3.42
8.1 (286)
6.7 (237)
5.3 (187)
4.6 (162)
18
0.18
40
96.6
7.5
11
39 / 34 / 29 / 26
57
600
28.1 (992)
22.4 (791)
35
5.22
1,130
94.1
5.4
32
38
48 / 45
63
Specifications
50Hz 230V
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=mł/min×35.3