Outdoor Unit / RK(X)S-C, ARK(X)S-C
Step
3
Remove the sheets of
putty.
Cut the pipe with a tube
cutter.
4
Heat up the brazed part
and withdraw the piping
with pliers.
184
Procedure
Tube cutter
SiENBE04-401A
Points
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Be careful so as not to break
the pipes by pressing it
excessively by pliers when
withdrawing it.
Removal Procedure