Daikin FTKS20CVMB Service Manual page 238

Inverter pair wall mounted type
Hide thumbs Also See for FTKS20CVMB:
Table of Contents

Advertisement

SiENBE04-401A
RXH20/25/35CVMB9, ARXH20/25/35CVMB9, RYN20/25/35CVMB9,
RXH20/25/35CAVMB, ARXH20/25/35CAVMB
indoor
X1M
1
1
2
2
3
3
RED
L
L
BLK
N
WHT
N
FIELD WIRING.
NOTE
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
X1M
: TERMINAL STRIP
C74 , C75 , C80
C94 , C95 , C100 : CAPACITOR
DB1 , DB2
: DIODE BRIDGE
FU1 , FU3
: FUSE
L
: LIVE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
PCB
: PRINTED CIRCUIT BOARD
Appendix
PCB
S
L1
FU3
20A
HL1
HN1
V2
MRL
SA1
V3
E
1
S70
Z2C
1 ~
outdoor
M1F
MRCW , MRL
MRM10 , MRM20
: MAGNETIC RELAY
N
: NEUTRAL
Q1L
: OVERLOAD PROTECTOR
R1T , R2T , R3T
: THERMISTOR
S20 , S70 , S80 , S90 : CONNECTOR
SA1
: SURGE ARRESTER
L1R
Z3C
MRM20
HR1
HR2
MRM10
FU1
3.15A
V1
C80
MRCW
1
6
3
6
3
1
S80
M
Y1R
R1T
R2T
R3T
( OUTDOOR )
( DISCHARGE )
( CONDENSER )
Z1C , Z2C , Z3C : FERRITE CORE
IC11
: TRIAC
IPM1
: INTELLIGENT POWER MODULE
V1 , V2 , V3
: VARISTOR
Y1E
: ELECTRONIC EXPANSION VALVE COIL
Y1R
: REVERSING SOLENOIDE VALVE COIL
: PROTECTIVE EARTH
Wiring Diagrams
DB1
~
+
C74
DB2
+
-
~
~
+
-
C100
C75
-
~
+
IC11
-
OL1
1
6
OL2
S20
S90
6
X30A
M
Y1E
Q1L
IPM1
+
C94
+
-
C95
+
-
-
W
V
U
W
V
U
1
Z1C
N=5
V
W
U
M1C
3D042575B