SETUp & TESTINg

HVAC INSTAllER SYSTEM SETTINgS TAblE

The following table contains the system settings and their details . Default settings are shown in bold . Some settings
are only available dependent upon the value of other settings .
System setting
Description
01 . Equipment Type
Equipment type set by SW1 .
02 . Temperature Scale
Set the thermostat to Fahrenheit or Celsius
mode .
03 . Reversing Valve
Selects O or B operation.
04 . Control Setup
Used to lockout heating or cooling outputs.
Note: Only available if Equipment Type is set to
Heat/Cool .
05 . Heat/Cool: Cooling Stages
Heat/Cool: Number of Cooling Stages.
Heat Pump: Compressor
Heat Pump: Number of Compressor Stages.
Stages
06 . Heat/Cool: Heating Stages
Heat/Cool: Number of Heat Stages.
Heat Pump: Aux Heat
Heat Pump: Number of Auxiliary Heat Stages.
Stages
07 . Heat/Cool: Fan Control
Heat/Cool: Determines if the thermostat or
in Heating
equipment controls the fan in heating .
Heat Pump: Auxiliary
Heat Pump: Auxiliary Equipment type.
Equipment Type
08. Extended Fan – Heat
Extends fan operation after heat call ends.
09. Extended Fan – Cool
Extends fan operation after cool call ends.
10 . Temperature Sensor Offset
Field adjustment of controlling temperature
sensor(s) .
11 . Humidity Offset
Field adjustment of internal RH sensor.
12 . Auto Changeover
Enable or disable auto changeover mode .
13 . Deadband
Auto Changeover mode deadband .
14 . Remote Sensor
Select if remote sensor is attached, and if it is
attached, if it is the primary control or averaged
with the built-in sensor . If the remote sensor is
the primary control it can be configured to use
the built-in sensor as a back-up sensor .
15 . Outdoor Sensor
Select if outdoor sensor is attached or not .
18. Compressor Min Off Time
Minimum off time for compressor protection.
19. Heating Min Off Time
Minimum off time for heating.
20. Equipment Min On Time
Minimum on time for heating and cooling.
8
factory default setting (bold)
and setting range
Heat/Cool
Heat Pump
fahrenheit
Celsius
O – On in cooling
B – On in heating
Heat and Cool
Heat Only
Cool Only
One
Two
One
Two
gas/Oil Heat (equipment controls fan)
Electric Heat (thermostat controls fan)
Disable
Enable (90 second extension)
Disable
Enable (90 second extension)
0° (no offset applied)
-4°F to +4°F (-2°C to +2°C)
0 (no offset applied)
-5% to +5%
Disable
Enable
3°f (1.5°C)
2°F to 9°F (1°C to 4.5°C)
Not installed
Control no backup
Control with built-in backup
Average with thermostat built-in sensor
Not installed
Installed
5 minutes
1 to 5 minutes
2 minutes
1 to 5 minutes
2 minutes
1 to 5 minutes
SETUp & TESTINg
HVAC INSTAllER SYSTEM SETTINgS TAblE
System setting
Description
21 . Auto Changeover Time
Minimum time between heating and cooling
calls .
22 . First Stage Differential
First differential .
23 . Second Stage Differential
Second stage differential .
24 . Third Stage Differential
Third stage differential .
25 . Fourth Stage Differential
Fourth stage differential .
26 . Away
Enables the Away feature . The Away feature
allows the Aprilaire mobile and web apps to use
a single button press to set the thermostat to a
predefined setpoint(s) . The thermostat will hold
the setpoint(s) until Away is canceled with the
app or at the thermostat .
27. Heat Blast
Enables the Heat Blast feature.
28. Blast Offset
Amount of heating when Heat Blast is initiated.
37 . Stage Rate
Accumulation of equipment run time in
equipment staging determination .
1 = more rapid staging of equipment (comfort) .
5 = slower staging of equipment (economy) .
38 . Progressive Recovery
Enable or disable progressive recovery .
39. Low Balance Point
Outdoor temperature low balance point .
Note: This option is only available if the outdoor
sensor is enabled .
40. High Balance Point
Outdoor temperature high balance point .
Note: This option is only available if the outdoor
sensor is enabled .
41 . Program Format
Enables the 7 day program .
42 . Reset Service Reminders
Clears the Change Air Filter and HVAC and
Dehumidifier Service reminders if they are active
and resets the start date to the current date .
Clears the Change Water Panel reminder if it is
active. If the reminder is set to Timed, the clock
will be reset .
43 . HVAC Service Reminder
The period for displaying the "HVAC Service
Reminder" message.
44. Constant Backlight
Enable constant, low intensity backlight when
24VAC is present .
45. Backlight Intensity
Set the active backlight intensity .
Note: The minimum setting is 40% when
Constant Backlight is enabled.
(CONTINUED)
factory default setting (bold)
and setting range
4 minutes
1 to 5 minutes
1°f (0.5°C)
1°F to 9°F (0.5°C to 4.5°C)
1°f (0.5°C)
1°F to 9°F (0.5°C to 4.5°C)
1°f (0.5°C)
1°F to 9°F (0.5°C to 4.5°C)
1°f (0.5°C)
1°F to 9°F (0.5°C to 4.5°C)
Disable
Enable
Disable
Enable
3°f (1.5°C)
3°F to 5°F (1.5°C to 2.5°C)
2
1 to 5 or "OFF" to ignore accumulated
run time .
Disable
Enable
20°f or -8°C
0°F to 60°F (-18°C to 12°C) or OFF to
ignore LBP
65°f or 14.5°C
0°F to 80°F (-18°C to 22°C) or OFF to
ignore HBP
7-Day
Non-Prog
No
Yes
Off
1 to 12 months or "Off" to disable
Disable
Enable
100 percent
0 to 100 Percent
9