Machine Operation

Pre-run Machine Inspection

Do a pre-run inspection to find possible problems that
could cause poor performance or lost time from break-
down. Follow the same procedure each time to avoid
missing steps.
NOTE:
See maintenance service schedule for daily
inspection items.

Starting Machine

NOTE: Perform pre-run machine check before
operating machine.
Before starting machine, make
FOR SAFETY:
sure that all safety devices are in place and
operating properly.
1. Turn the machine power on.
2. Release the parking brake, if your machine is
equipped with this option.
3. Engage the direction propel levers for the desired
direction.

Emergency Stop Procedures

1. Release the propel levers.
2. Turn machine power off with key switch.
3. If an electrical problem is suspected push in
emergency stop button, if machine is equipped
with this option.
4. Apply brakes, if your machine is equipped with this
option.
18

Filling Solution Tank

1. Turn the machine power off.
2. Set the parking brake if your machine is equipped
3. Remove solution tank cover.
4. Fill the solution tank with clean water, leaving
5. Measure the chemical into the solution tank. Liquid
6. Replace solution tank cover.
Flammable materials can cause an explosion or
fire. Do not use flammable materials in the tanks.
Les matières inflammables peuvent provoquer une
explosion ou un incendie. Ne pas utiliser de
matériaux inflammables dans les réservoirs.
86400260 Manual Operators - Cutter 24V Deluxe
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
with this option.
enough room for the required amount of cleaning
solution. The solution tank capacity filled to 2" (5
cm) from bottom of fill inlet is 23 gallons (87 liters).
The water must not be hotter than 140° F (60°C) to
prevent damage to the tank.
chemicals should be added to the solution tank
after filling with water. Dry chemicals should be
thoroughly mixed before being added into solution
tank. Commercially available, high alkaline floor
cleaners, are suitable for use in the solution
system.
NOTE: Read the chemical manufacturers
recommended proportion instructions.