5.2 U.S. and Canada installation/ 4-wire branch circuit
Refer to Figure 2,
-
Separate the green or yellow-green wires from
the white wires that extend out of the end of the
appliance cable.
-
The ground wire must be connected first;
-
Connect the green or yellow-green ground wire
from the appliance to the ground wire in the
junction box (green colored wire) using UL/CSA
listed wire connectors. Do not connect the
grounding wire to the neutral wire in the
junction box.
-
Connect the red and black leads from the
appliance to the matching color wires in the
junction
connectors.
-
Connect the white wire from the appliance to the
neutral white wire in the junction box using a UL/
CSA listed wire connector.
Connect to a 20A fuse or circuit breaker. Connect to copper wire, or, if connection is made to aluminum
house wiring, use UL-listed or CSA-approved connectors approved for joining aluminum and copper
wiring.
NOTE: Both leads coming out of the range must be connected according to the diagrams shown in
Figures 1 and 2