Clearances - Empire Comfort Systems DVLT36FP92N-2 Installation Instructions And Owner's Manual

Luxury direct vent gas fireplace
Hide thumbs Also See for DVLT36FP92N-2:
Table of Contents

Advertisement

Clearance to Combustibles
Back
Side
Floor
Top Stand-off
Top Framing Edge
Minimum Height Floor To Ceiling
Vertical Venting
Optional Recessed Area
If a recess is desired, a 5-1/2" (127mm) deep (face of finishing
material to back of pocket) may be framed. Use 3/4" (19mm) wood
or steel framing. See Figure 1.
Television Considerations
Installing a television above a fireplace has become a desirable
feature; however, the following information should be considered.
All fireplaces, whether decorative or heater rated create heat.
Most television manufacturers recommend not placing a television
near a heat source. Because there is a large variety of television
manufactures, styles and sizes, it is impractical to test every potential
installation. If you choose to install a television above or near your
fireplace, understand that Empire Comfort Systems accepts no
responsibility for this decision and any injury or damage due to this
application is the sole responsibility of the owner. Additionally, it is
highly recommended to turn off the fireplace and let it cool down
before servicing or using the operational buttons located on the
television. In all cases, the television manufacturer's instructions
and warnings should be followed.
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can ignite
combustibles. See Figure 3.
34829-3-0515

CLEARANCES

1-1/2" (38 mm)
1-1/2" (38 mm)
0" (0 mm)
12" (305 mm)
12" (305 mm)
96" (2439mm)
1" (25.4 mm)
Figure 1
Mantel Chart
* IMPORTANT NOTE:
NO COMBUSTIBLES MAY BE PLACED IN THE
AREA BETWEEN THE TOP OF THE FIREPLACE
OPENING TO THE MANTLE
MANTEL
(304 mm)
14"
(355 mm)
* 19-3/8"
(492 mm)
TOP EDGE OF FIREPLACE
TOP OF FIREPLACE OPENING
Ceiling Height and Side Wall Clearances
Minimum ceiling height is 96" (2438 mm)
Clearance from side of fireplace to adjacent sidewall is 6" (152mm).
56"
(1422mm)
MIN.
Figure 2
17-1/2"
(444.5mm)
12"
Figure 3
15"
(381mm)
Figure 4
Page 7

Advertisement

Table of Contents
loading