Specifications; Cranking System Specifications; Tightening Torque Specifications; Special Tools And Equipment - Suzuki 2006 SX4 Service Manual

Hide thumbs Also See for 2006 SX4:
Table of Contents

Advertisement

1I-9 Starting System:
Front Housing Bush
Inspect the bush for wear or damage. Replace if
necessary.

Cranking System Specifications

Voltage
Output
Rating
Direction of rotation
Brush length
Number of pinion teeth
Performance
No load characteristic
Around at 20 °C
Load characteristic
(68 °F)
Locked characteristic
Magnetic switch operating voltage

Tightening Torque Specifications

Fastening part
Starting motor battery cable nut
NOTE
The specified tightening torque is also described in the following.
"Starting Motor Dismounting and Remounting"
"Starting Motor Components"
Reference:
For the tightening torque of fastener not specified in this section, refer to "Fasteners Information in Section 0A".

Recommended Service Material

NOTE
Required service material is also described in the following.
"Starting Motor Components"

Specifications

12 volts
1.2 kW
30 seconds
Clockwise as viewed from pinion side
Standard: 12.3 mm (0.48 in.)
8
Condition
90 A maximum
11.0 V
2370 r/min minimum
7.5 V
10.65 N⋅m (1.065 kgf-m, 7.70 lb-ft) minimum
300 A
840 r/min minimum
780 A maximum
4.0 V
20 N⋅m (2.0 kgf-m, 14.5 lb-ft) minimum
8 volts maximum
N⋅m
9.8

Special Tools and Equipment

Guarantee
Tightening torque
kgf-m
lb-ft
0.98
7.0
I2RH01190024-01
S6RW0D1907002
Limit: 7.0 mm (0.28 in.)
S6RW0D1907003
Note