Electrical Connection - Dimplex VFMi 20 C Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Electrical Connection

15. Carry out the electrical connection to the terminal strip of the device.
Connection example: With heating contactor and wall-mounted thermostat.
Circuit diagram legend
A1/Z1, A2/Z2 - Control signal AC charge control
K1
- Heating contactor
L1, L2, L3
- External conductors
LE
- Fan control
LH
- Supplementary heating control
M1
- Fan motor
N
- Neutral conductor
PE
- Protective conductor
R1-R3
- Heating elements
R7
- Series resistor for fan (not all types)
Please observe your local technical connection requirements.
With a fixed connection thermust be an all-pole head release devise connected in series with at least 3 mm clearance between
it and the device. This requirement is met with circuit breakers for example.
For start-up see the following page.
Reinsert the front and side panels and fasten the screws. Reverse dismounting procedure.
18
R8
- Control resistors (charging)
R9
- Supplementary heating (accessories)
RTR
- Room temperature controller (accessories)
STR1, STR2 - Safety temperature controller
TB
- Temperature limiter
TR
- Charge controller
TR9
- Supplementary heating temperature
controller
TRG
- Ventilation grid temperature controller
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfmi 40 cVfmi 30 cVfmi 60 cVfmi 70 cVfmi 50 c

Table of Contents