Electrical Connection; General Information; Wall Mounting - Dimplex B075E Installation And Operating Instructions Manual

Mk1 oil-filled radiator
Table of Contents

Advertisement

Available languages

Available languages

This guide is for quick reference only
To view the full manual, please visit - www.dimplex.nl
Energy Related Product Directive
This product complies with Lot20 of the Energy Efficiency Directive (2015/1188)
Type of heat output/ room temperature control
With electronic room temperature control
Electronic room temperature control plus week
timer
With open window detection
Model Identifier(s):
Nominal heat
Pnom
output
Height (mm)
Width (mm)
Depth (mm)
Minimum heat
Pmin
output (indicative)
Maximum continu-
Pmax,c
ous heat output
Auxiliary electricity Consumption
At nominal heat
elmax
output
At minimum heat
elmin
output
In standby mode
elSB
With open window detection

General Information

Please read the instructions closely before first using the product.
The necessary wall mounting brackets are provided with the product as a
standard.
It should only be operated when in the upright position as shown - see Fig.1.
All models are IP20 rated. Before connecting the heater check that the supply
voltage is the same as that stated on the heater.
For further information on heater guards, please contact our guard supplier
direct on Tel. No. 020 7987 1184 or visit www.aianos.co.uk, or in case of difficulty
or for further advice contact the Customer Helpline.

Wall Mounting

IMPORTANT - The radiator must only be mounted using the kit supplied
WARNING - This product is heavy and care should be taken in installation
Select a suitable position on a wall, near to a mains power outlet. The radiator
should not be mounted closer than 75mm from the floor - see Fig. 2 (to enable
cleaning), or adjacent side walls. Ensure at least 305mm clear space between
the radiator and any overhanging shelf. It should not be mounted closer than 1
metre from the ceiling.
STEP 1: Check that you have all the necessary components:
(a) 2 x Bottom wall brackets
(b) 2 x Top wall brackets
(c) 2 x Radiator securing brackets
(d) 2 x Self-tapping screws.
STEP 2: Using a straight edge, draw a horizontal line (see 'Y' in Fig. 2) for the
bottom brackets at the required mounting height from the floor.
NOTE - The bottom of the radiator must not be less than 75mm from the
floor. To achieve this the top edge of the bottom brackets must be at least
160mm from the floor - see Fig 2. On this line, mark off the fixing centres
according to model - see `C' in the table in Fig. 1 and Fig. 2
IMPORTANT - For safe clearances from shelf/obstacle - see Fig. 5
Yes
Yes
Yes
B075E
C100E
D150E
0.75 kW
1 kW
1.25 kW
659
659
659
570
840
1105
50
50
50
0.75 kW
1.00 kW
1.25 kW
0.75 kW
1.00 kW
1.25 kW
0.00
0.00
0.00
0.00
0.00
0.00
<0.0005
<0.0005
<0.0005
Yes
Place the bottom brackets centrally over these centres with the top row of holes
on the line, and mark the fixing hole positions – see Fig. 2.
STEP 3: Drill the holes and fit wall plugs. Screw the bottom brackets in position
– see Fig. 2.
STEP 4: Measure dimension D in Fig. 1 according to model, from the top of the
bottom brackets and draw a horizontal line. Mark off the fixing centres for the
top brackets in line with the bottom brackets. Place each top bracket on the
line and mark the fixing holes – see Fig. 3. Drill and plug the wall and fix the
top brackets in place.
STEP 5: Place the radiator on the bottom brackets, then fit each securing
bracket to the top of the radiator and secure it with the self-tapping screw
provided – see Fig. 4.
Check that the radiator is securely fixed to the wall.
E200E
1.5 kW
WARNING - THIS APPLIANCE MUST BE EARTHED
659
The electrical installation must be carried out by a competent electrician,
and be in strictaccordance with the current I.E.E. Regulations for Electrical
1373
Equipment in Buildings. The wires in this mains lead are coloured in accordance
50
with the following code:
1.5 kW
GREEN AND YELLOW:
BLUE:
BROWN:
1.5 kW
The heater is fitted with a length of flexible cable type H05VV-F size 3 x
1.0mm2 for connection to the fixed wiring of the premises through a suitable
connection box positioned adjacent to the heater.
0.00
A means for disconnection must be incorporated in the fixed wiring of the
0.00
premises in accordance with the wiring rules. The supply circuit to the heater
must incorporate a double pole isolating switch having a contact separation
<0.0005
of at least 3mm.
'Y'

Electrical Connection

EARTH
NEUTRAL
LIVE
'C'
75
75
mm
mm
(min)
(min)
Fig. 4
Fig. 2
Fig. 3
Fig. 5
93
mm
(max)
305
mm
(min)