Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Overload: Slow down or
Fault
raise deck
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Mower's action
type
Disables Blades
Disables Blades
Disables Blades
Disables Blades
Disables Blades
Disables Blades and Drive
Disables Blades
Disables Blades
Disables Blades
Code
number
Trigger
(engineering
screen)**
2
Phase over current
4
Current sensor calibration
8
Not used
16
Controller temperature is
o
over 100
C
32
Motor hall sensor fault
64
Controller under voltage
128
POST static gating test
512
Instantaneous phase over
current
1024
Motor has reached at tem-
perature of 105
Possible causes
Motor pulling too much
current, short bursts
Internal controller issue
Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller
Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor
Battery voltage too low,
poor connection, corrosion
Controller failure
Motor pulling too much
current, short bursts
Motor over loaded, faulty
o
C