Connecting The Server To The Mains - Fujitsu PRIMERGY RX2530 M1 Operating Manual

Hide thumbs Also See for PRIMERGY RX2530 M1:
Table of Contents

Advertisement

Hardware installation
5.4

Connecting the server to the mains

In its basic configuration level the server has a hot-plug power supply unit.
A second hot-plug power supply unit can be added to ensure a redundant power
supply. If one power supply unit is defective, the other then guarantees
unimpaired operation. Each hot-plug power supply unit can be replaced during
operation (see the "PRIMERGY RX2530 M1 Server Upgrade and Maintenance
Manual").
V
CAUTION!
The PSU is automatically set to a mains voltage in the range 100 - 240 V
(PSU Platinum) or 200 - 240 V (PSU Titanium). You may only operate the
server if its rated voltage range corresponds to the local mains voltage.
Ê Connect the power cord to the server power supply unit.
Ê Connect the mains connector to an outlet on the rack's socket strip (see also
Technical Manual for the rack).
I
A phase redundancy in the power supply of the server can be set up if
two hot-plug power supply units are installed.
In this case, each of the power supply units is either connected to two
different phases or to two separate circuits of the internal power supply
network.
54
Operating Manual
RX2530 M1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents