Fujitsu PRIMERGY RX2530 M1 Operating Manual page 27

Hide thumbs Also See for PRIMERGY RX2530 M1:
Table of Contents

Advertisement

Ambient conditions
Environment class 3K2
Environment class 2K2
Temperature
Operation (3K2)
Transport (2K2)
Humidity
Condensation during operation must be avoided!
Noise level
The acoustic noise values are depending on the system configuration.
Sound power level L
(ISO 9296)
Sound pressure level at
adjacent workstation
L
(ISO 9296)
pAm
RX2530 M1
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
5°C ... 40°C (with Cool-safe
10°C ... 35°C (without Cool-safe
-25°C ... 60°C
10% ... 85% (non condensing)
min. configuration
1xPSU 1xCPU
< 5.1 B (standby)
WAd
< 6.2 B (operation)
< 34 dB(A) (standby)
< 44 dB(A) (operation)
Operating Manual
Functional overview
®
ATD)
max. configuration
2xPSU 2xCPU
< 5.3 B (standby)
< 7.7 B (operation)
< 36 db(A) (standby)
< 60 db(A) (operation)
®
ATD)
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents