Ohms Measurement; Continuity Test - Fluke 1587 FC User Manual

Hide thumbs Also See for 1587 FC:
Table of Contents

Advertisement

1587 FC/1587/1577
Users Manual

Ohms Measurement

Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
[2]
50.0 MΩ
[1]
Accuracies apply from 0 % to 100 % of range.
[2]
Up to 80 % relative humidity.
Overload Protection ............................................ 1000 V rms or dc
Open Circuit Test Voltage ................................... <8.0 V dc
Short Circuit Current ........................................... <1.1 mA
Diode Test (all 1587 models)
Diode Test Indication .......................................... Display voltage drop: 0.6 V at 1.0 mA nominal test current:
Accuracy ............................................................. ±(2 % + 3)

Continuity Test

Continuity Indication ........................................... Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open Circuit Voltage ........................................... <8.0 V
Short Circuit Current ........................................... 1.0 mA typical
Overload Protection ............................................ 1000 V rms
Response Time ................................................... >1 m sec
Frequency Measurement (all 1587 models)
Range
99.99 Hz
999.9 Hz
9.999 kHz
99.99kHz
38
Accuracy all 1587 models
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 KΩ
0.001 MΩ
0.01 MΩ
Resolution
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
[1]
+(% of Rdg+Counts)
+(% of Rdg+Counts)
±(0.9 % + 2)
±(1.5 % + 3)
Accuracy ±(% of Rdg+Counts)
±(0.1 % + 1)
±(0.1 % + 1)
±(0.1 % + 1)
±(0.1 % + 1)
[1]
Accuracy 1577
±(1.2 % + 2)
±(2.0 % + 3)