8-2. CAPACITY AND THE INPUT CURVES
MXZ-2B20NA
7.2
11.2
13.5
6.7
10.3
12.4
6.1
9.5
11.5
5.6
8.6
10.4
5.0
7.9
9.5
7.0
8.6
4.7
4.1
6.3
7.6
47.5
22.1
32.8
40.9
43.7
20.5
30.2
37.6
40.1
18.7
27.7
34.6
36.5
17.1
25.2
31.3
22.7
28.3
32.8
15.3
29.2
13.7
20.2
25.0
25.6
11.9
17.6
22.0
22.0
10.3
15.1
18.9
18.2
8.5
12.6
15.7
6.8
10.1
12.6
14.6
OBH560G
Cooling capacity
14.4
1.5
13.1
1.4
12.1
1.3
11.2
1.2
10.1
1.1
9.0
1.0
8.1
0.9
14
23
32
41
Outdoor intake air Dry-bulb temperature(°F)
Total input (Cooling :
1.3
1.2
1.1
1.0
0.9
0.8
14
23
Heating capacity
(at Rated frequency)
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
5
14
23
32
Outdoor intake air Wet-bulb temperature (°F)
NOTE: The above broken lines are for the heating operation without any frost and defrost operation.
(at Rated frequency)
Indoor intake air Wet-bulb
temperature(°F)
79
50
59
68
77
86
95
at Rated frequency
32
41
50
59
68
77
Outdoor intake air Dry-bulb temperature (°F)
59
1.3
68
79
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
41
50
59
5
32
75
72
68
64
104
113
)
72
75
79
68
64
Indoor intake air Wet-bulb
temperature( F)
86
95
104
113
Total input (Heating
: at Rated frequency
14
23
32
41
Outdoor intake air Wet-bulb temperature (°F)
)
79
68
59
50
59