Mitsubishi Electric MXZ-2B20NA Service Manual page 25

Hide thumbs Also See for MXZ-2B20NA:
Table of Contents

Advertisement

MXZ-5B42NA
R.V. coil
Refrigerant flow in cooling
OFF
ON
Refrigerant flow in heating
Indoor unit
E
Indoor unit
D
Indoor unit
C
Indoor unit
B
Indoor unit
A
Indoor unit
A
Strainer
#100
Indoor unit
B
Strainer
#100
Indoor unit
C
Strainer
#100
Indoor unit
D
Strainer
#100
Indoor unit
E
Strainer
#100
OBH560G
Compressor
Discharge
temperature
thermistor RT62
Oil separator
High-pressure
Solenoid
switch
valve
Service port
4-way valve
Stop valve
(with service port)
Muffler
Service port
Capillary tube
O.D. 0.16 x I.D. 0.11 x 3.94
LEV A
Stop valve
Strainer
#100
LEV B
LEV C
LEV D
LEV E
Service port
Capillary tube
O.D. 0.10 x
I.D. 0.02 x 39.37
Accumulator
LEV F
25
Unit: inch
FAN-OUT
Outdoor
Ambient
heat
temperature
exchanger
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor
RT68
Defrost thermistor
RT61
Capillary tube
O.D. 0.14 x I.D. 0.09
x 23.6 (x 1)
Strainer #50
O.D. 0.14 x I.D. 0.09
x 19.7 (x 3)
Distributor
O.D. 0.14 x I.D. 0.09