D. Thimble Installation
ATTIC INsULATION shIELD NOT REqUIRED WhEN
ThIMbLE AppLICATION Is UsED.
The thimble must extend completely through the roof
structure shielding combustible materials. Five location
holes have been provided to allow for a variety of ceiling/
roof thicknesses. The thimble extension is required
when the ceiling/roof thickness exceeds 12 1/2 in. The
extension should overlap the thimble 1 in.
Drill 1/8 in. holes through the outer shield of the thimble
using the predrilled holes in the extension as guides.
Attach the extension to the thimble using the screws
provided with the extension.
Install the thimble assembly and nail/screw it securely
to the framing members.
Center the flashing over the chimney and fasten it
appropriately to the roof using nails or screws. Keep gaps
between the flashing plate and the roof to a minimum.
Caulk the flashing plate and roof junction as well as the
vertical seam on the flashing. All nail/screw heads must
be caulked with a roofing sealant.
Finish assembling the chimney, storm collar and
termination cap following the installation instructions
provided with them.
NOTE: Roofing shingles must be below the flashing plate
on the lower side of a sloped roof and over the flashing
plate on the sides and top.
Figure 5.6
MH Installation
16
Heatilator • MEL36, MEL42 Installation Manual • 4044-212 • Rev D • 01/06/15