D. Thimble Installation
ATTIC INsULATION shIELD NOT REqUIRED WhEN
ThIMbLE AppLICATION Is UsED.
•
The thimble must extend completely through the roof
structure shielding combustible materials. Five location
holes have been provided to allow for a variety of ceiling/
roof thicknesses. The thimble extension is required
when the ceiling/roof thickness exceeds 12 1/2 in. The
extension should overlap the thimble 1 in.
•
Drill 1/8 in. holes through the outer shield of the thimble
using the predrilled holes in the extension as guides.
Attach the extension to the thimble using the screws
provided with the extension.
•
Install the thimble assembly and nail/screw it securely
to the framing members.
•
Center the flashing over the chimney and fasten it
appropriately to the roof using nails or screws. Keep gaps
between the flashing plate and the roof to a minimum.
•
Caulk the flashing plate and roof junction as well as the
vertical seam on the flashing. All nail/screw heads must
be caulked with a roofing sealant.
•
Finish assembling the chimney, storm collar and
termination cap following the installation instructions
provided with them.
NOTE: Roofing shingles must be below the flashing plate
on the lower side of a sloped roof and over the flashing
plate on the sides and top.