E. Sidewalls/Surrounds
•
Locate adjacent combustible sidewalls a minimum of
12 in. (305 mm) from fireplace opening.
•
Mantle leg, surround, stub wall, whether combustible
or non-combustible, may be constructed as shown in
Figure 6.11.
FLUSH
FRONT
11 1/4 in.
[286 mm]
12 in.
[305 mm]
Figure 6.11 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening)
Heatilator • MEL36, MEL42 Installation Manual • 4044-212 • Rev D • 01/06/15
BRICK
FRONT
A
B
12 in.
[305 mm]
4 in.
[102 mm]
9 3/4 in.
[248 mm]
Fireplace
Opening
Model #
in.
ME L36
mm
in.
ME L42
mm
A
B
Outside
Dimensions
36
41
914
1041
42
47
1067
1194
23