C. Termination Requirements
•
Install a cap approved and listed for this fireplace system.
•
Locate cap where it will not become plugged by snow or other materials.
•
Locate cap away from trees or other structures.
•
The bottom of the termination cap must be at least 3 ft (.91 m) above the roof AND at least 2 ft (.61 m) above any portion
of roof within 10 ft (3.05 m).
Slanted Roofs
Chimney must
extend 3 ft (.9 m)
above the roof
Flat Roofs
Chimney must
extend 3 ft (.9 m)
above the roof
Figure 4.3
Termination Cap Locations
Heatilator • MEL36, MEL42 Installation Manual • 4044-212 • Rev D • 01/06/15
Chimney must extend 2 ft (.6 m)
above any portion of the roof or
adjacent structures within
10 ft (3 m) of the chimney
Chimney must extend 2 ft (.6 m)
above any portion of the roof or
adjacent structures within
10 ft (3 m) of the chimney
13