Icom IC-910H Instruction Manual page 61

Vhf/uhf all mode transceiver
Hide thumbs Also See for IC-910H:
Table of Contents

Advertisement

Preamplifier controller for 430(440) MHz
Switch the preamplifier control capability ON and
OFF. When using the optional AG-35, ON must be se-
lected. Otherwise, the preamplifier is never activated.
DO NOT connect any equipment, such as an SWR
or power meter, between the transceiver and pre-
amplifier. In such case, the preamplifier may not
activate properly.
Preamplifier controller for 1200 MHz
Switch the preamplifier control capability ON and
OFF. When using the optional AG-1200, ON must be
selected. Otherwise, the preamplifier is never acti-
vated.
DO NOT connect any equipment, such as an SWR
or power meter, between the transceiver and pre-
amplifier. In such case, the preamplifier may not
activate properly.
CI-V address
To distinguish between equipment, each CI-V trans-
ceiver has its own Icom standard address in hexa-
decimal code. The IC-910H's address is 60H.
When 2 or more IC-910Hs are connected to an op-
tional CT-17
-
CI
V LEVEL CONVERTER
address for each IC-910H in the range 01H to 7FH.
CI-V baud rate
Select transfer rate for CI-V remote control from Auto,
300, 1200, 4800, 9600 and 19200 bps.
CI-V transceive
Transceive operation is possible with the IC-910H
connected to other Icom transceivers or receivers.
When "on" is selected, changing the operating fre-
quency, operating mode, etc. on the IC-910H auto-
matically changes those of connected transceivers (or
receivers) and vice versa.