SC748TQ-R1200 (tower/4U rackmount)
Dimensions (as tower): (WxHxD) 7 x 17.8 x 29.4 in. (178 x 452 x 747 mm)
Weight
Gross (Bare Bone): 65.5 lbs. (29.8 kg.)
System Cooling
Six heavy-duty 8-cm cooling fans (fan speed controlled by BIOS setting)
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 6A (115V) to 15A (240V)
Rated Input Frequency: 50-60 Hz
Power Supply
Rated Output Power: 1200W w/PFC (Part# PWS-1K22-1R)
Rated Output Voltages: +3.3V (20A), +5V (20A), +12V (100A), -12V (0.6A), +5Vsb
(4A)
Power Supply Effi ciency Rating: 91% (peak)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions:
FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant
UL Listed (USA)
CUL Listed (Canada)
TUV Certifi ed (Germany)
CE Marking (Europe)