Item No.
U403
Adjusting margins for scanning an original on the contact glass
Description
Adjusts margins for scanning the original on the contact glass.
Purpose
Make the adjustment if margins are incorrect.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
Display
A Margin
B Margin
C Margin
D Margin
6. Change the setting value using the cursor left/right keys or numeric keys.
Increasing the value makes the margin wider, and decreasing it makes the margin narrower.
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U403
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Description
Description
Scanner left margin
Scanner leading edge margin
Scanner right margin
Scanner trailing edge margin
Scanner leading edge margin
(3.0 ± 2.5 mm)
Scanner
left margin
(2.5 +1.5/-2.0 mm)
Scanner trailing edge margin
(3.0 ± 2.0 mm)
Figure 1-3-16
U404
( P.1-3-57)
1-3-56
Setting
Initial
range
setting
0 to 10.0
2.0
0 to 10.0
2.0
0 to 10.0
2.0
0 to 10.0
2.0
Scanner
right margin
(2.5 +1.5/-2.0 mm)
2K3/2L3
Change in
value per step
0.5 mm
0.5 mm
0.5 mm
0.5 mm