Kyocera FS-6025MFP/B Service Manual page 194

Hide thumbs Also See for FS-6025MFP/B:
Table of Contents

Advertisement

4. Remove all connectors from DP main
PWB.
5. Remove five clamps and then remove
the waires from holder.
6. Remove two screws and then remove
the holder.
7. Remove six screws and then remove
the DP main PWB.
8. Check or replace the DP main PWB
and refit all the removed parts.
CAUTION: When replacing the DP
main PWB, remove the EEPROM from
the DP main PWB that has been
removed and then reattach it to the new
DP main PWB.
Screw
Holder
Screw
DP main PWB
Screw
Screw
Screw
DP main PWB
1-5-32
Wires
Figure 1-5-55
Screw
Screw
Screw
Figure 1-5-56
2K3/2L3-1
Clamps

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 305Fs-6030mfpTaskalfa 255/b