Filling Water Softener with Water:
1. Connect the MP-MCA control valve transformer into the electrical
outlet provided.
2. Press and hold the REGEN button until the drive motor starts. When
the drive motor stops, the display will read "RINSE" position.
3. Press the REGEN again until the drive motor starts. When the drive
motor stops, the display will read "BRINE" position.
4. Press the REGEN again until the drive motor starts. When the drive
motor stops, the display will read "RINSE" position. The fast rinse
position will rinse the softener tank.
5. Open the inlet ball valve a ¼ turn of its full open position to allow
water to enter the water softener mineral tank slowly. The water is
going to enter the tank from the bottom of the distributor pipe and
leave the tank from the top. This will slowly purge all the air from the
tank.
IF WATER ENTERS THE TANK TOO FAST, ALL THE CATION
RESIN WILL BE FLUSHED TO DRAIN DURING START UP.
6. When only water is running to the drain, open the inlet and outlet ball
valves fully.
7. Press and hold the REGEN button until the drive motor starts. When
the drive motor stops, the display will read "FILL" position. The brine
tank will fill with the proper amount of water.
NOTE: THE TIMER WILL AUTOMATICALLY ADVANCE TO THE
SERVICE POSITION AND THE DISPLAY WILL READ THE CAPACITY
REMAINING, IN GALLONS.