Troubleshooting - Master MP-CLR-30 Installation And Operation Manual

Uf top mount water softeners

Advertisement

Problem: Water conditioner fails to regenerate. No soft water.
Possible Cause
Power supply to MP-Clear
Reflections control has been
interrupted.
Water pressure lost.
Corrupted programming of MP-
Clear Reflections timer.
Defective MP-Clear Reflections
timer.
No salt in brine tank.
Manual bypass valve is open.
Leak at riser pipe seal.
Insufficient brine.
Plugged injector or injector screen.
Possible Cause
Plugged injector or injector screen.
Insufficient water pressure.
Corrupted programming of MP-
Clear Reflections timer.
Defective MP-Clear Reflections
timer.
Obstructed drain line.

Troubleshooting

Determine reason for power
interruption and correct. Reset time of
day.
Restore water pressure.
Reprogram timer assembly.
Replace timer assembly.
Add salt and regenerate.
Close manual bypass valve.
Insure that riser pipe is properly
sealed at o'ring seal. Inspect pipe for
cracks.
Check brine float height and clean
assembly if necessary. Check flow
rate capabilities of safety float and air
check assembly.
Inspect and clean injector and/or
injector screen.
Problem: No Brine Draw
Inspect and clean injector and/or
injector screen.
Increase water pressure above 25
psig (172kPa) minimum.
Reprogram timer assembly.
Replace timer assembly.
Remove obstruction.
12
Solution
Solution