Installation and Operation Manual
MP-CLR UF Top Mount Water
Softeners
June 2015 Version

Advertisement

loading

Summary of Contents for Master MP-CLR-30

  • Page 1 Installation and Operation Manual MP-CLR UF Top Mount Water Softeners June 2015 Version...
  • Page 2: Table Of Contents

    Table of Contents Page Topic Description Model # and Packaging Packaging Information Component Packaging Description Packaging Description System Media Media Packaging Softening System System Positioning Water Softener Tank Loading Filling with Media MP-Clear Reflections Control Valve Attaching Valve to Tank MP-Clear Reflections Control Valve Attaching Valve, cont’d Service &...
  • Page 3 Installation and Operating Instructions for MP-CLEAR REFLECTONS UPFLOW CONTROL Top Mount Water Softener Model #: _______ MP-CLR-30 UF 1.0 CF Water Softener _______ MP-CLR-45 UF 1.5 CF Water Softener _______ MP-CLR-60 UF 2.0 CF Water Softener _______ MP-CLR-75 UF 2.5 CF Water Softener...
  • Page 4: Water Softener Tank Loading

    Water Softener Positioning: 1. Place water softener in desired position, far enough from walls and other obstructions to allow for servicing the unit. 2. Place the water softener within reasonable access to a grounded 115V/60 HZ circuit and a legal drain line connection. Water Softener Tank Loading: (Only the MP-CLR-75 needs to be loaded)) 1.
  • Page 5 1. Turn the control valve upside down and ensure that the control valve distributor o’ring is in place. Use silicone lubricant on the o'ring. **DO NOT USE PETROLEUM!** **USE ONLY SILICONE ** 2. Place the control valve onto the distributor pipe and into the tank opening.
  • Page 6: Service & Drain Piping

    Service and Drain Piping: 1. Pipe water softener into the service lines. The inlet and outlet connections of the control valve are 1” copper or PVC and are located on the back of the valve body. As you face the timer the inlet is on the right and the outlet is on the left.
  • Page 7 MP-CLR SERIES SOFTENER Treated Air Gap Drain Master Water Conditioner Well Tank Brine tank Overflow fitting to floor drain gravity NOTE: All Master Water Conditioners must be installed after the well tank or water meter if its public water supply.
  • Page 8 Electrical Requirements: Always follow all local electrical codes when installing our water treatment equipment. 1. Provide an 115v/60Hz properly grounded dedicated electrical Outlet. (It’s very important that the polarity be correct) Avoid using outlets that are switch controlled. 2. Maximum amperage required is 5 amps. 3.
  • Page 9 Filling Water Softener with Water: 1. Connect the MP-MCA control valve transformer into the electrical outlet provided. 2. Press and hold the REGEN button until the drive motor starts. When the drive motor stops, the display will read “RINSE” position. 3.
  • Page 10: Mp-Clear Reflections Control Valve

    2) To change the number, use the UP or DOWN arrows. 3) Press the NEXT button. If water was tested by Master Water Conditioning, follow recommendations on water analysis, for hardness setting. Regeneration Day Override Setting (the factory default is OFF) 1) Press the NEXT button.
  • Page 11 Final Check: 1. Fill the brine tank with Solar Salt and the Res-Up Feeders with Res- Up (one quart is provided). 2. Make sure the drain line connection meets all plumbing codes and that the drain line size can handle the backwash flow rate of the softener.
  • Page 12: Manual Regeneration

    Manual Regeneration: Note: For softeners, if brine tank does not contain salt, fill with salt and wait at least 2 hours before regeneration. To initiate manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to regenerate immediately.
  • Page 14: Troubleshooting

    Troubleshooting Problem: Water conditioner fails to regenerate. No soft water. Possible Cause Solution Power supply to MP-Clear Determine reason for power Reflections control has been interruption and correct. Reset time of interrupted. day. Water pressure lost. Restore water pressure. Corrupted programming of MP- Reprogram timer assembly.
  • Page 15 Problem: Insufficient brine draw Possible Cause Solution Partially clogged injector or injector Inspect and clean injector and/or screen. injector screen assembly. Restricted flow rate in brine line. Check flow rate capabilities of the safety float/aircheck assembly. Insufficient water pressure. Increase water pressure above 25 psig (172kPa) minimum.
  • Page 16 Problem: Leak to Drain Possible Cause Solution No flow control installed in drain Install drain line flow control. line. Insufficient water pressure. Increase water pressure above 25 psig (172kPa) minimum. Damaged valve disk or obstruction Inspect and if damaged, replace all in valve disk.
  • Page 17 Problem: Timer does not display time of day Possible Cause Solution AC Adapter unplugged Connect power No electric power at outlet Repair outlet or use working outlet Defective AC Adapter Replace AC Adapter Defective PC Board Replace PC Board Problem: Timer does not display correct time of day Possible Cause Solution Switched outlet...
  • Page 18 Problem: Control valve does not regenerate automatically when UP and DOWN buttons are held and depressed Possible Cause Solution AC adapter unplugged Connect AC adapter No electric power at outlet Repair outlet or use working outlet Broken drive gear or drive cap Replace drive gear assembly assembly Defective PC board...
  • Page 19 ERROR CODES...
  • Page 21 CLEAR REFLECTIONS PARTS...
  • Page 22 CLEAR REFLECTIONS PARTS...
  • Page 23 CLEAR REFLECTIONS PARTS...
  • Page 24 CLEAR REFLECTIONS PARTS...
  • Page 26: Warranty

    All defective parts shall be returned prepaid to Master Water Conditioning Corporation for inspection. Master shall not be liable for labor charges other than Master factory repairs. This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
  • Page 27 MP-CLR-XXX UF METER SOFTENER NORMAL VIEW CURRENT TIME 6:35 TIME SOFTENING NEXT CURRENT FLOW RATE NEXT IN GALLONS PER MINUTE NEXT TOTAL GALLONS CUMULATIVE SINCE START-UP* NEXT CAPACITY REMAINING CAPACITY REMAINING CHANGES SOFTENING IN GALLONS NEXT OVERRIDE ONLY DISPLAYS IF REGENERATION DAY OVERRIDE IS PROGRAMMED IN DAYS...
  • Page 28 INSTALLER SETTINGS NEXT HARDNESS NEXT DAY OVERRIDE (Default is OFF) NEXT REGEN TIME: HOUR NEXT REGEN TIME: MINUTES SET TIME CLOCK CLOCK TO CHANGE TIME USE 12:00...
  • Page 29 REFERENCE ONLY VALVE PROGRAMING NEXT NEXT CAPACITY __ x 1000 X1000 NEXT SET SYSTEM Softening TYPE NEXT RESERVE Auto CAPACITY SET BRINE NEXT TYPE NEXT REGENERATION NORMAL TIME NEXT BRINE REFILL NEXT Post TIME NEXT RELAY 1 BRINE NEXT NEXT RELAY 2 BACKWASH NEXT...
  • Page 30 REFERENCE ONLY VALVE PROGRAMING NEXT NEXT SET SYSTEM Normal TYPE NEXT VALVE SIZE NEXT DELTA Dp OFF PRESSURE ONLY NEXT SET 2 NEXT SET 3 NEXT SET 4...
  • Page 31 MCA BOARD VALVE HISTORY DIAGNOSTICS (3 SEC) DAYS SINCE LAST REGENERATION NEXT MAXIMUM FLOW RATE SINCE START-UP IN GPM GALLONS SINCE LAST REGENERATION NEXT NEXT GALLONS TREATED SINCE START-UP (X1000) RESERVE CAPACITY CALCULATED PER DAY NEXT IN GALLONS NEXT DAYS SINCE START-UP USAGE PER DAY NEXT IN GALLONS...
  • Page 32 MANUAL REGENERATION PRESS ONCE FOR NEXT REGEN TIME REGEN PRESS AGAIN TO CANCEL REGENERATION PRESS AND HOLD FOR 3 SECONDS FOR IMMED PRESS IN REGEN TO ADVANCE TO NEXT CYCLE LOCKING SETTINGS AFTER SETTING A VALUE… NEXT REGEN LOCK/UNLOCK: (IN SEQUENCE)
  • Page 33 ERROR CODES...