Quick Links

Installation and Operation Manual
MBA-MM-1040/10/13/1665
MULTI MEDIA FILTERS
263/742 Logix Control Valve
MASTER
Water Conditioning Corp.
www.masterwater.com
with the
June 2010

Advertisement

loading

Summary of Contents for Master MBA-MM-1040

  • Page 1 MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010...
  • Page 2 Table of Contents Page Topic Description Model # and Packaging Packaging Information Component Packaging Packaging Description Description System Description Valve Description Filter Positioning System Positioning Multi Media Filter Tank Loading Filling with Media Logix 263/742 Control Valve Attaching Valve to Tank Figure 1 &...
  • Page 3 Installation and Operating Instructions for 263/742 Logix Top Mount Multi Media Filter Model #: _______ MBA-MM-1040 1.0 CF Multi Media Filter _______ MBA-MM-10-1 1.5 CF Multi Media Filter _______ MBA-MM-13-1 2.5 CF Multi Media Filter _______ MBA-MM-1665-1 4.0 CF Multi Media Filter...
  • Page 4 Shipping Carton Description / unit: # of Contents Description cartons Mineral tank Distributor pipe installed 263/742 263/742 timer and backwash flow Logix control control and bypass with 1” copper or valve pvc connection #1 Sand #0 Sand #45 Sand #0 Sand Philterkol Note: all units have a Vortech distributor and do not require gravel.
  • Page 5 3. Cover the top opening of the distributor pipe before filling the tank with media. Model # Gravel 1 Sand 0 Sand 45 Sand 0 Sand Philterkol MBA-MM-1040 12 lbs. 8 lbs. 25 lbs. 17 lbs. 13 lbs. MBA-MM-10 20 lbs.
  • Page 6 1. When facing the front of the Logix timer, the inlet connection is located on the left and the outlet connection is on the Figure 1) right. The control valve's inlet and outlet connections are either 1” copper or PVC equipped with gasket and nut. Figure 1 Install the 263 bypass valve (See Figure 2) with inlet and outlet handles facing upward.
  • Page 7 DO NOT OVERTIGHTEN! **DO NOT USE PETROLEUM!** **USE ONLY SILICONE ** Service and Drain Piping: 1. Pipe Multi Media Filter into the service lines .The inlet and outlet connections of the control valve are 1” copper or PVC and are located on the back of the valve body.
  • Page 8 • Never decrease the drain piping size to below ¾” • Maximum drain line length is 30 feet. • Maximum drain line height is 6 feet above the control valve. • The drain line must be piped to an open air gap (See Figure 3) •...
  • Page 9 Typical Piping Layout Treated water Air Gap Drain Untreated to outside Master Water Conditioner Well Tank Untreated water from well NOTE: All Master Water Conditioners must be installed after the well tank or water meter if its public water supply.
  • Page 10 Electrical Requirements: Always follow all local electrical codes when installing our water treatment equipment. 1. Provide an 115v/60Hz properly grounded dedicated electrical Outlet. (It’s very important that the polarity be correct) Avoid using outlets that are switch controlled. 2. Maximum amperage required is 5 amps. 3.
  • Page 11 Filling Multi Media Filter with Water: Figure 4 1. Push the FOR REGENERATION button (Figure 4) on the controller down for 5 seconds. This will initiate a manual regeneration. You will notice a flashing hour glass during regeneration. The controller will indicate that the motor is turning the camshaft to cycle C1 (BACKWASH).
  • Page 12 Logix Control Valve Timer Settings: Note: The control valve is set at the factory. You only need to set the time of day and regeneration time if required, which is preset at 1 am. Figure 5 Time of Day Setting 1) Press the SET button.
  • Page 13 Specification Reference Table Model # Conditioned Backwash Backwash Slow Rinse Fast Rinse Water Flow Required Timing Timing Timing Rate MBA-MM-1040 5.0 gpm 6.0 gpm 0 Minutes 10 Minutes Minutes MBA-MM-10 5.0 gpm 6.0 gpm 0 Minutes 10 Minutes Minutes MBA-MM-13 8.0 gpm...
  • Page 14 Troubleshooting Symptom: Water conditioner fails to regenerate. Dirty water. Possible Cause Solution Power supply to 742 control has Determine reason for power been interrupted. interruption and correct. Reset time of day. Water pressure lost. Restore water pressure. Corrupted programming of 742 Reprogram timer assembly.
  • Page 19 All defective parts shall be returned prepaid to Master Water Conditioning Corporation for inspection. Master shall not be liable for labor charges other than Master factory repairs. This warranty gives you specific legal rights, and you may have other rights which vary from state to state.