OPERATION

CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
SHOCK HAZARD
DO NOT splash or pour water
or grease onto control panel
or wiring.
IMPORTANT:
The ventilator cannot operate
if the filter pack is removed or
clogged.
It is the responsibility of
the store management to
maintain sufficient spares
of filter packs to avoid
prolonged shutdown of the
ventilator when this filter is
expended.
Filter packs cannot be
cleaned.
Wells Manufacturing assumes
no liability for loss of business
due to filter related shutdown.
Filters that are not genuine
Wells Replacement Parts
may cause your unit to
operate incorrectly and you
will risk the possibility of
voiding your warranty.

Control Panel

NOTE: Cooking appliances must be operated in accordance with the
manufacturer's instructions.
During normal operation, the illuminated power switch will be the only
light on the control panel that will be ON.
If the CHECK FILTERS light illuminates, check BAFFLE FILTERS,
PREFILTERS, and the HEPA AIR FILTERS for proper installation.
If the REPLACE PRE-FILTERS light illuminates .. Replace the Pre-filters.
If the REPLACE FILTER PACK light illuminates, replace the FILTER
PACK.
NOTE: the REPLACE FILTERS PACK light is a warning that filter pack is
nearing the end of its service life. The ventilator will continue to operate
for a period of time after the REPLACE FILTER PACK LIGHT turns ON
to allow continued operation through a peak period. However, filter pack
must be replaced within a short time period or it will clog, disabling the
ventilator and appliances.
If the SERVICE REQUIRED light illuminates, the filter pack is restricted
to the point of insufficient airflow for proper operation and the Ventilator
will shut down until the underlying clogged filter situation has been
corrected. Replace clogged item with a fresh filter to correct the
condition.
Reset the unit by turning VENTILATOR POWER SWITCH to OFF,
then back to ON.
A failure of incoming electric power will cause a shut down of the unit.
Reset the unit by turning VENTILATOR POWER SWITCH to OFF, then
back to ON.

Operation Lights

There are two equipment lights that provide illumination of the working
area. These lights are controllled by the main power switch.
ON
POWER
CHECK
REPLACE
OFF
FILTER
PREFILTER
REPLACE
SERVICE
FILTER PACK
REQUIRED
18
IL2736