INSTALLATION

FILTER INSTALLATION

Note air flow direction arrow on filter pack. Remove old filter pack
and slide new filter pack fully into the appropriate slot. Verify that
the airflow arrow points toward the fan.
The bafffle filter is reusable and should be cleaned at least weekly.
Change the pre-filter and Hepa filter pack as indicated on the front
panel. These filters are disposable and cannot be reusable. All filters
are accessible throught the front service door.
Use only genuine Wells replacement parts and filters,
call (314) 678-6314 or your authorized Wells service agent. Parts
supplied by others will void your warranty and may not provide safe
operation.
BAFFLE FILTER and GREASE CUP INSTALLATION
1.
Install baffle filter from front. Engage the baffle filter in the retainer
slot. Push up until the baffle filter bottom clears the lower lip of the
retainer, then lower the baffle filter into the bottom retainer
2.
Install GREASE CUP into brackets below the baffle filter.
Note: Failure to install the GREASE CUP will allow grease and
moisture from the BAFFLE FILTER to drop into hot cooking surfaces,
creating both a SAFETY HAZARD (hot oil splatter).
HEPA FILTER
PRE-FILTER
BAFFLE-FILTER
IL2738
17
NOTE:
The BAFFLE FILTERS,
PRE-FILTERS and FILTER
PACK actuate position
switches when they are
properly positioned. They
must be properly installed
for the under hood cooking
appliance contactor to be
energized.
WARNING
SLIP AND FALL
HAZARD
DO NOT operate any
grease-producing cooking
appliance unless the grease
cup is properly installed. Oil
will drip onto floor creating a
slipping hazard.
CAUTION
BURN HAZARD
DO NOT operate any cooking
appliance unless the grease
cup is installed.
Moisture dripping onto hot
surfaces, oil or grease can
cause splattering.
WARNING
CLEAN FILTERS
DO NOT attempt to wash the
HEPA / charcoal fliter pack or
pre-filter. Water absorbtion
will render the filter unusable.
Use of a wet or clogged filter
will cause the ventilation
system to shut down. Use
only clean Wells
Authorized
®
Service Parts. Keep spare
filter packs on hand to avoid
distruptions. Wells Parts
Department (314) 678-6314.