OPERATION

CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
SHOCK HAZARD
DO NOT splash or pour water
or grease onto control panel
or wiring.
IMPORTANT:
The ventilator and cooking
appliance control relay are
disabled when REPLACE
FILTERS light is illuminated.
Note that the ventilator
cannot operate if the filter
pack is removed.
It is the responsibility of
the store management to
maintain sufficient spares
of filter packs to avoid
prolonged shutdown of the
ventilator when this filter is
expended.
Filter packs cannot be
cleaned.
Wells Manufacturing
assumes no liability for loss of
business due to filter related
shutdown.
Control Panel
ON
POWER
OFF
CHECK
FILTER
NOTE: Cooking appliances must be operated in accordance with the
manufacturer's instructions.
During normal operation, VENTILATOR POWER ON (illuminated power
switch) will be the only light on the control panel that will be ON, when
the unit is operating properly.
If the CHECK FILTERS light illuminates, check both GREASE BAFFLE
and the HEPA AIR FILTER for proper installation.
If REPLACE FILTER light illuminates, replace FILTER PACK.
NOTE: REPLACE FILTERS light is a warning that filter pack is nearing
the end of its service life. The ventilator will continue to operate for
a period of time after REPLACE FILTER LIGHT turns ON to allow
continued operation through a peak period. However, filter pack must
be replaced within a short time period or it will clog, disabling the
ventilator.
If SERVICE REQUIRED light illuminates, filter pack is restricted to
the point of insufficient airflow for proper operation. Ventilator is shut
down until the underlying clogged filter situation has been corrected.
Replace clogged item with a fresh filter pack to correct the condition.
Reset the unit by turning VENTILATOR POWER SWITCH to OFF, then
back to ON.
A failure of incoming electric power will cause a shut down of the unit.
Reset the unit by turning VENTILATOR POWER SWITCH to OFF, then
back to ON.
Operation Lights