3. Mode switch
OP
OP X/Z
PGM1
PGM2
(SRV)
(SRV')
* The key can be removed in the REG or OFF position.
* In the SRV' mode, key inputs are prohibited and no display is
made.
* With the key in the off position power is still supplied to the
main PWB.
[Functions]
Function for each key position
SRV':
System reset
SRV:
Service mode (Service programming)
PGM2:
Allows programming of an item that is not changed
frequently, in addition to the PGM1 mode program-
ming.
PGM1:
Allows programming of items frequently changed
(e.g. department, PLU pricing, and discount rate set-
ting).
OP/XZ:
Allows X or Z operation by servers or cashiers.
REG:
Allows registrations.
MGR:
Allows the operations, by authorized person such as
a manager (e.g. correction after transaction finished
or cancellation of entry limits), which are not permit-
ted to ordinary cashiers.
X1/Z1:
Allows reading and resetting of a day's sales total.
X2/Z2:
Allows reading or resetting sales totals in a specified
period.
& :
Switches off the display to prevent keyboard entries.
(The setting does not turn off the AC
power.)
4. Display
1) Layout
Operator display
1
L2
L3 CHR. SML
DC
VP STOCK RCPT
ST
OFF
SRV
MA
SM.
REG
MGR
X1/Z1
X2/Z2
Fig. 3-1
ONL
TL
/RF VAT
GC
CCD
SHIFT
COPY
Fig. 4-1
No. of positions
Color of display
Character size
6.6 (H)
2
Customer display
7
6
5
4
ST
TL
/RF
No. of positions
7
Color of display
Green
Character size
10 (H)
Lamps
Display
contents
L2
The lamp lights up when PLU level is 2.
L3
The lamp lights up when PLU level is 3.
CHR.
The lamp lights up when character key sheet mode in
text setting
SML
The lamp lights up when small characters are being
inputted in text setting
DC
The lamp lights up when double width characters are
being inputted in text setting.
ONL
The lamp lights up when the machine is connected to
the online transmission line; and it goes off when the
machine is disconnected from the line. The lamp
blinks during data transmission.
VP
The lamp lights up when Validation print is under
compulsion.
STOCK
The lamp lights up when stock is empty state.
RCPT OFF The lamp lights up when receipt is OFF state.
ST
The lamp lights up when a subtotal is displayed.
The lamp lights up when change amount is displayed
after tendering.
TL
The lamp lights up when a transaction is finalized with
CASH, CHECK, CREDIT, or CHARGE key, however,
the lamp does not light up when a transaction is
finalized with an amount tendered entry.
" / RF
The lamp lights up when the void or refund key is
pressed.
VAT SHIFT The lamp lights up when the vat shift key is pressed.
GC COPY
The lamp lights up when the guest check copy mode.
CCD
The lamp lights up when the CCD registration.
5. Printer (DP-730)
1) Specifications
Part number:
No. of stations:
Printing system:
Direction of printing:
Printing capacity:
– 4 –
Dot display
7 segment display
12
10
Green
Green
4.6 (W) mm
10.0 (H)
3
2
1
Fig. 4-2
4.5 (W) mm
Description
DP-730
2
Mechanical serial dot
Bidirectional
Receipt – 24 characters
Journal – 24 characters
Validation – 55 characters
(one line only)
4.3 (W) mm