Page 1
SERVICE MANUAL ER-A457 ONLINE COMMUNICA TION FUNCTION ELECTRONIC CASH REGISTER MODEL ER-A457 MODEL (For "V" version) CONTENTS CHAPTER 1. OVERVIEW ........1 CHAPTER 2.
Page 2
This is a specification of the on-line data communication via RS-232 interface of the ER-A457 It enables the ER-A457 to perform on-line communication. For on-line data communication a ER-457 can be connected to a host computer. Also, their connection can be made via modems.
Page 3
CHAPTER 3. SPECIFICATIONS OF CHAPTER 4. SIGNAL CONNECTION RS-232 INTERFACE DIAGRAM 1. Online interface 1. Connection between the master (Host) and Satellite a) Interface : RS-232 b) Duplex type : Half-duplex / Full-duplex c) Line configuration : Direct connection/Modem connection 25PIN D-SUB 9PIN D-SUB d) Data rate...
Page 4
2. Connection between the terminal and MODEM 25PIN D-SUB 9PIN D-SUB MODEM TERMINAL FRAME GROUND is connected to the shield of the cable. SD : TRANSMITTED DATA RD : RECEIVED DATA DTR : DATA TERMINAL READY DSR : DATA SET READY RTS : REQUEST TO SEND DCD: DATA CARRIER DETECTOR CTS : CLEAR TO SEND...
Page 5
CHAPTER 7. DATA BLOCK FORMAT Example Memory image 1. Basic format 1) ID-ENQ : 10bytes Line image ENQ code (05h) Terminal No. 000001-999999 (6 bytes) Transmission sequence EOT is set as dummy cahracters. (3 bytes) 2) ACK : 1 byte 06h 3) NAK : 1 byte 15h CHAPTER 8.
Page 6
[JOB#6111] MRS = 00 Programming of the modem control 6111 6111-A: 1. Sensing of the CI signal Yes/No 1. Sensing of the CI signal 6111-A 6111-B: 1. Duplex type 1. Duplex type 6111-B Full duplex system Half duplex system [JOB#6112] MRS = 5 Programming of the transmission baud rate 6112 6112-A: Transmission baud rate...
Page 7
COPYRIGHT 2001 BY SHARP CORPORATION All rights reserved. Printed in Japan. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.