Precor 9.23 Service Manual page 35

Hide thumbs Also See for 9.23:
Table of Contents

Advertisement

9.
Connect the black wire removed in step 3 to the T4 (M-) terminal of the lower PCA, the red
wire removed in step 3 to the T3 (M+) terminal of the lower PCA and the green -yellow lead
to its frame ground termination.
10. Dress the drive motor wires and fasten them in place with cable ties.
11. Check treadmill operation per Procedure 3.
9.23, 9.27 Treadmill