Junction Box Wiring - Monessen Hearth KHLDV400 Install And Operation Instructions

Khldv series direct vent gas fireplace
Table of Contents

Advertisement

MILLIVOLt - OptIOnaL Fan/BLOwer SySteM
junction Box
Figure 28 -
Junction Box Wiring Diagram
FP1912
7. Remove the access covers on the right and left side walls

Junction box wiring

of the firebox toward the front by unfastening the screws.
nOte: the access covers are not identical. Figure 31
8/08
8. Two screws are already mounted to each cover which would
be utilized to mount the blower to the cover. Unfasten the two
screws and mount the blower bracket assemblies. Figure
33
9. Consult blower wiring diagram and start the assembly. Fig-
ures 28 & 29 It is helpful to wire the right blower, the speed
control, the fan limit switch, and the power cord first. Then
plug in the power cord to the junction box and secure the right
cover plate/blower assembly to the side of the firebox.
10. Assemble the wire clips provided with the blower kit to the
right and left sides of the fireplace through existing holes on right and left.
11. Run the wire harness down the right and snap wires into the clips assembled in #10. Run the two
wires along the glass track, on the floor of the unit, in front of the firebox
12. Snap the fan limit switch behind the clip already assembled to the side of the firebox on the front
right hand side. Figure 32
13. Secure the left access plate/blower assembly to the left side of the firebox. Run the two wires men-
tioned earlier up the left firebox wall and snap wires into clip assembled in #10 on the outer shell
wall. Make the connection to the left blower. Replace the refractory and hearth
refractory (pull away from burner toward the front).
14. Replace side panels attached to the glass frame assembly with the louvered side
panels provided with the blower kit by unfastening the four nuts for each cover
door. (Do not overtighten or stud may break off.) Use three metal clip screws
provided with kit to secure the wire assembly in the front beneath the access
cover. Page 13, Figure 7
15. Install the speed control (rheostat switch) on the side above the existing one used
for the light (discard the plate sent with the switch as it will not be needed.
16. Replace logs.
17. Replace the glass.
18. Replace the front plate below the glass frame. nOte: the front plate hides the
wire harness in the front.
73D0024
120V AC
60Hz
Factory Supplied
Not Supplied
Blue
Junction Box
Blue
Black
Hi-Temp
T-Stat Sensor
Black
Blower
Rheostat
Figure 29 -
Blower Wiring Diagram
Failure to replace the access cover with the one
provided with the blower kit, and then running
FP2135
blower wiring diagram
the blower, will cause excessive temperatures
and could cause a fire, property damage and/or
loss of life.
Electrical Grounding Instructions: This appli-
ance is equipped with a three-prong (grounding)
plug for your protection against shock hazard
and should be plugged directly into a properly
grounded three prong receptacle.
KHLDV Series Gas Fireplace
Black
Right 
Hi-Temp
Blower
Left 
Blower
White
Figure 30 -
Location of White Dial on
Speed Control
25