WIRING JUNCTION BOX

1. Before installing, wire the receptacle into an electrical
circuit. This should be done before framing the fire-
place. Wire with minimum 60° C wire in accordance
with prevailing codes.
2. Remove the cover plate located on the outer shell-
right side.
3. Loosen two screws on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screws.
4. Make all necessary wire connections and reattach the
cover plate to the outer shell.
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
Junction Box
Figure 12. Junction Box Wiring Diagram
FP1912
Junction box wiring
8/08
WARNING
!
Factory Supplied
Not Supplied
Monessen • AVFLST42 Installation Instructions • 4118-900 Rev. B • 05/2020
Electrical connections should only be performed by
a qualified licensed electrician. Main power supply
must be turned off before connecting to the main
electrical power supply or performing service.
Electrical Grounding Instructions:
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three prong receptacle.
IMPORTANT: Always check local building codes. This in-
stallation must comply with local regulations as well as
the National Electric Code.
120V AC
60Hz

ELECTRICAL INSTALLATION