Key Combinations For System Settings - Vermont Castings KSTDV500(N/P)TSCSB Installation And Operating Instructions Manual

Kstdv series direct vent gas fireplace
Table of Contents

Advertisement

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
Either mode benefi ts from the instantaneous battery back-
up, so you never have to worry about a power outage.
NOTE: The Signature Command System comes standard
in the Intermittent Pilot mode, so you must follow the in-
structions below to switch to Standing Pilot Mode if needed.
Intermittent/Standing Pilot Setup (Default intermittent)
1. Holding the ON button on the Command Center while
turning on the master switch will toggle between stand-
ing pilot and intermittent pilot.
2. After the above operation, one beep (for standing pi-
lot) or two beeps (for intermittent pilot) will be given as
confi rmation.
Six-hour Safety Shutdown Option (Default ON)
1. The system comes preset from the factory with a six
(6) hour shutdown from its last command of operation.
This is done to prevent the fi replace from continuing to
operate if unattended. You may disable this feature if
you wish.
NOTE: By disabling this feature, your fi replace may con-
tinue to operate unattended.
2. When the master switch is in the ON position ("-"),
pressing the ON button and the OFF button on the
Command Center simultaneously will toggle between
enabling and disabling the six-hour shutdown option.
3. After the above operation, one beep (for enabling the
six-hour shutdown option) or two beeps (for disabling the
six-hour shutdown option) will be given as confi rmation.
Function
Intermittent/Standing
Pilot Setup
Standing Pilot Temp.
Shutoff
RF Remote Receiver
On/Off
Learn Remote Trans-
mitter
6-hour safety shut-
down setup
20306743
Operation
Hold the ON  button while turning on the master switch (Beep once for
standing pilot, twice for intermittent pilot)
Hold the ON  button 3 seconds (when the master switch on the main
burner is off)
Push the RF receiver On/Off button on the control board
Hold the OFF  button while turning on the master switch (Beep twice
then press any handheld remote button)
Press the ON  button and OFF  button simultaneously (Beep once
for ON, twice for OFF)
KSTDV Series Gas Fireplace
Remote Transmitter Learn Function (Default OFF)
1. The RF receiver button located on the Control Board
must be in the on position before the learn function can
begin. Use paper clip to depress button. One beep for
RF receiver ON or two beeps for RF receiver OFF will
be given as confi rmation. Refer to Figure 42 for location.
2. After the RF receiver is on, holding the OFF button on
the Command Center while turning on the master switch
will activate the learn function for the transmitter.
3. After the above operation, two beeps will be given and
the green LED on the Command Center will fl ash for
10 seconds.
4. During the 10 seconds, press the OFF button on a
transmitter to learn. Another two beeps will be given
to confi rm a successful learning. Refer to transmitter
instructions for remote operations.
Shutting Off the Standing Pilot (Temporary Shut Off)
To shut off the standing pilot for service or summer shut
down, press and hold the ON button on the Command
Center for 3 seconds when the master switch is in the ON
position ("-") and the main burner is off.
Note: Pilot will resume the next time system is turned on.
KEY COMBINATIONS FOR SYSTEM
SETTINGS
NOTE: When On/Off wall switch is used, it must be in the
On position to perform all system setups.
Default Setting
Intermittent Pilot
RF OFF
ON
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kstdv500ntscKstdv500ptsc

Table of Contents