KSTDV Series Gas Fireplace
just the fl ame height according to the difference between
the Set temperature and the Room temperature. There is
no manual fl ame height adjustment. The fan speed will
also automatically adjust if turned on.
NOTE: When entering the Smart Mode
tion there will be a 1 second delay for the fl ame and blower
adjustment. When Smart Mode
tomatically, there can be up to a 3 minute delay for fl ame/
blower adjustment. Smart Mode
peratures every 3 minutes. Also see AUX Control.
1. When Set Temp. is 3° F or higher than Room Temp.,
fl ame height will be on High.
2. When Set Temp. is 2° F higher than Room Temp.,
fl ame height will be on Medium.
3. When Set Temp. is 1° F higher than Room Temp.,
fl ame height will be on Low.
4. When Set Temp. is equal to Room Temp., fl ame height
does not change (stays on low).
5. When Set Temp. is lower than Room Temp., the fi re-
place will be shut off.
6. When Set Temp. is 1° F higher than Room Temp.,
again the fl ame height will be on Low.
7. the fan speed follows the fl ame height, if the fan is
turned on.
®
To exit Smart Mode
thermostat and shut off the fi replace;
a. push and hold the THERMO buttons for 3 sec-
onds, Or
b. press the OFF button, Or
c. slide down on the arrow buttons.
To shut off the Smart Mode
to regular thermostat mode, press and hold the THERMO
button and the ON/UP button at the same time for 3 sec-
onds again.
Blower Speed Control
Figure 57
NOTE: Blower will only work with fl ame on.
The blower speed control function
is used to adjust the speed of the
blower connected to the Signature
Command System. There are four
speed levels, Off, Low, Medium,
High.
1. Press the FAN button to enter
the blower speed control mode.
The fan icon will start fl ashing.
2. Press the ON/up and OFF/down
button to increase/decrease the
blower speed.
3. Press the fan button again to
confi rm the speed setting. If the
fi replace is on, the blower speed
will take effect right away; if the
40
®
thermostat func-
®
thermostat operates au-
®
thermostat checks tem-
®
thermostat option and return
Figure 57
TOUCH SCREEN REMOTE CONTROL OPERATION
fi replace is off, the receiver will remember this setting
and the blower is still off (see blower On Delay and Off
Delay in the next section).
4. After the signal is sent, the ON/up and OFF/down but-
tons become fl ame height controller again.
5. When the fan button is fl ashing, slide up and down on
the arrow buttons will turn the blower speed to High
or Off directly without pressing the fan button again to
confi rm.
6. If the blower is turned on using the FAN button, the
blower speed will adjust automatically when using
®
Smart Mode
stat section).
Blower On Delay Time and Off Delay Time Setup
Figure 58
1. Hold the FAN button for 3 sec-
onds until two numbers appear
on the LCD screen. The left
number is blower On Delay and
the right number is blower Off
Delay Time.
2. When the fi rst number is fl ash-
ing, use the ON/up button to set
the desired On Delay Time from
0 to 15 min.
3. Press the OFF/down button to
jump to the Off Delay Time set-
up.
4. When the second number is
fl ashing, use the ON/up button
again to set the desired Off Delay Time from 0 to 15
min.
5. Press the OFF/down button again to fi nish the setup
and the new settings will be transmitted to the receiver.
6. The default settings are 5 minutes for the On Delay
Time and 8 minutes for the Off Delay Time, as shown.
Light Brightness Control
Figure 59
The light brightness control func-
tion is used to adjust the bright-
ness of the light bulbs connected
to the AC module on the Signature
Command System. There are four
light brightness levels defi ned:
Off, Low, Medium, High
1. Press the LIGHT button to en-
ter the light brightness control
mode. The LIGHT icon will
start fl ashing.
2. Press the On/up and OFF/
down buttons to increase/
decrease the light brightness
(Off-Low-Medium-High).
thermostat (See Smart Mode
Figure 58
Figure 59
®
thermo-
20306743