VENTING INSTALLATION

Read all instructions completely and
thoroughly before attempting installation.
Failure to do so could result in serious
injury, property damage or loss of life.
Operation of improperly installed and
maintained venting system could result in
serious injury, property damage or loss of
life.

INSTALLATION PRECAUTIONS

Consult local building codes before beginning the
installation. The installer must make sure to select the
proper vent system for installation. Before installing vent
kit, the installer must read this fi replace manual and vent
kit instructions.
Only a qualifi ed installer/service person should install the
venting system. The installer must follow these safety rules:
Wear gloves and safety glasses for protection.
Use extreme caution when using ladders or when on
rooftops.
Be aware of electrical wiring locations in walls and
ceilings.
The following actions will void the warranty on your venting
system:
Installation of any damaged venting component.
Unauthorized modifi cation of the venting system.
Installation of any component part not manufactured or
approved by Vermont Castings Group
Installation other than permitted by these instructions.
Horizontal sections of this vent system
require a minimum of 3" clearances to
combustibles at the top of the fl ue and 1"
clearance at the sides and bottom until the
fl ue penetrates the outside wall. A minimum
1" clearance all around the fl ue is acceptable
at this point of penetration. Unless the
1
vertical run is 7
2
of fi replace, the clearance for horizontal run
is 1" on all sides.
Vertical sections of this vent system require
a minimum of 2" clearance to combustibles
at the top of the unit directly above the
stand-off. A minimum of 1" clearance all
around the fl ue is acceptable thereafter.
20306743
feet or higher from fl oor
KSTDV Series Gas Fireplace
**1"
**1"
72"
(1829 mm)
Figure 7 -
Combustible Clearances for Vent Pipe
* A minimum of 3" clearance to the top is required along
horizontal length until fl ue pipe penetrates outside wall.
** A minimum 1" clearance to combustibles permitted all
around fl ue at outside wall
This fi replace must be vented to the outside.
The venting system must NEVER be attached
to a chimney serving a separate solid fuel
burning appliance. Each gas appliance must
use a separate vent system. Do not use
common vent systems.
Failure to follow these instructions will
void the warranty.
*3"
24"
(610 mm)
FP2567
11